Sensor adjustment via teach input (pin 5)
Teach-in
To teach, a teach signal is applied to the teach input (pin 5). The duration of the
teach signal (low level on the teach input) determines the teach-in function.
NOTICE
Before a low level is applied for teaching-in functions, a high level must
be applied for at least 20 ms.
8
A
Buttons locked
B
Buttons can be operated
C
Teach is started
D
Teach duration
Note: During the teach duration, the label tape must be transported through
the sensor (see chapter "Manual teach while the label tape is passing
through (dynamic)").
E
Teach is ended
9
A
Buttons locked
B
Buttons can be operated
T
Duration of the teach signal
Duration T
[ms]
Function
220 … 280
Configure the switching behavior of the switching output: light
switching
320 … 380
Configure the switching behavior of the switching output: dark
switching
420 … 480
easyTune (-): reduce sensitivity
520 … 580
easyTune (+): increase sensitivity
10
EN
Содержание 50142875
Страница 2: ...1Bildteil 1 A B 2 12 s 2 7 s C B A D 7 s 2...
Страница 3: ...3 4 2 7 s 5 12 s 3...
Страница 4: ...6 2 s 2 s 7 7 s 8 A B C t HIGH LOW t 100 ms t 20 ms D E t 20 80 ms 20 ms 4...
Страница 5: ...9 A B T t HIGH LOW 20 ms 20 ms 10 5...