Adjusting the switching behavior of the switching output (light/dark

switching)

5

Ä

Press the teach button until only the green ON LED flashes.

Ä

Release the teach button. 
The green ON LED flashes for another 2 seconds and the yellow OUT LED
indicates the changed switching behavior for 2 seconds:

– Yellow OUT LED ON: switching output, light switching (signal in the label

gap)

– Yellow OUT LED OFF: switching output, dark switching (signal on the label)

easyTune – Manual fine tuning of the switching threshold

With homogeneous label material, the signal in the gap between two labels is
much larger compared to the signal on the label. 
For the taught switching threshold, there is a high function reserve in both the gap
as well as on the label, and the sensor functions reliably.
To achieve a better function reserve, it can be advantageous to change the taught
switching threshold, especially for inhomogeneous label material.
The sensitivity of the sensor and, thus, the switching threshold can be adjusted
with the 

easyTune function, which is in principle comparable to a potentiometer.

6

The sensitivity of the sensor can be adjusted by pressing the teach button (+) or
the minus button (-).

Increase sensitivity:

Ä

Briefly press the teach button (+).

ð

A single flash of the green ON LED confirms button actuation.

Reduce sensitivity:

Ä

Briefly press the minus button (-).

ð

A single flash of the yellow OUT LED confirms button actuation.

8

EN

Содержание 50142875

Страница 1: ...GSU 14E Ultrasonic label fork Leuze electronic GmbH Co KG info leuze com In der Braike 1 73277 Owen Tel 49 7021 573 0 We reserve the right to make changes 2020 04 23 50143645 www leuze com...

Страница 2: ...1Bildteil 1 A B 2 12 s 2 7 s C B A D 7 s 2...

Страница 3: ...3 4 2 7 s 5 12 s 3...

Страница 4: ...6 2 s 2 s 7 7 s 8 A B C t HIGH LOW t 100 ms t 20 ms D E t 20 80 ms 20 ms 4...

Страница 5: ...9 A B T t HIGH LOW 20 ms 20 ms 10 5...

Страница 6: ...l material used determines the achievable precision and the reliability of gap detection between labels Light switching signal in the label gap Dark switching signal on the label 1 A Label center posi...

Страница 7: ...chronously Release the teach button Allow the label tape to advance through the sensor at a maximum speed of 50 m min The sensor indicates the belt transport by a more rapid synchro nous flashing of t...

Страница 8: ...signal on the label For the taught switching threshold there is a high function reserve in both the gap as well as on the label and the sensor functions reliably To achieve a better function reserve...

Страница 9: ...the sensor downward shift of the switching threshold Repeatedly press the teach button briefly until the sensor detects the moving carrier tape without labels stably and without flickering Manual lock...

Страница 10: ...ated C Teach is started D Teach duration Note During the teach duration the label tape must be transported through the sensor see chapter Manual teach while the label tape is passing through dynamic E...

Страница 11: ...s also possible to lock the buttons via the teach input pin 5 A static high signal 20 ms on the teach input locks the buttons on the de vice so that no manual operation is possible The buttons can the...

Отзывы: