Commissioning and configuration
Leuze electronic
RFM - HF RFID Series
49
TNT
35/7-2
4
V
Notice!
• The RFM 12 can only process 1 transponder in the field at a time.
• The RFM 32 can process up to 4 transponders simultaneously in the field
(commands ’
N
’ and ’
W
’).
• The RFM 62 can process up to 8 transponders simultaneously in the field
(commands ’
N
’ and ’
W
’).
Attention!
Any settings that are made do not take effect until transferred to the device!
Operation mode tab
The operation mode setting is important for automatic operation of the device. Here, you
set the function after activation/trigger (operation mode) and memory access (block
number).
Figure 7.3:
RF-Config – Operation mode tab
Start block, number of blocks and block size are transponder dependent (see table 7.1). If
selected but not present, an error message is output.
For the "Write" online command, the
Precharge
function can also be set. In this case, the
write data are transferred to the read/write system before the transponder to be written is
located in the field. When the transponder does enter the field, it is automatically written
with the precharged data.