Commissioning
Leuze electronic
OGS 600
83
TNT
35/7-2
4
V
8.4.1
CANopen system commands
Commands can be sent to the sensor via CAN index 2000
h
System Command
.
Table 8.18:
System commands
8.5
Performing a reset on the OGS 600
Two different resets can be performed by means of system commands:
• The
device reset
restarts the software of the OGS 600.
All settings are retained.
• The
factory reset
resets all internal settings of the device to the factory settings. This
includes all indices as well as settings determining which trace type is active and which
filters are active.
Command
Value
Function / description
Dec.
Hex
Device Reset
128
d
80
h
Software
reset
Factory reset
130
d
82
h
Reset to factory settings
Activation
176
d
B0
h
Sensor illumination ON
Deactivation
177
d
B1
h
Sensor illumination OFF
UART Boot
180
d
B4
h
Start UART boot loader
Teach: on trace mode 4
192
d
C0
h
Trace width, trace amplitude, minimum contrast
Teach: angle compensation measure-
ment
193
d
C1
h
Angle
compensation
teach
Teach: on trace mode 1
194
d
C2
h
Trace width only
Teach: on trace mode 2
195
d
C3
h
Minimum contrast only
Teach: on trace mode 3
196
d
C4
h
Trace amplitude only
Dark trace, light background
212
d
D4
h
Light trace, dark background
213
d
D5
h
Retro-reflective trace
214
d
D6
h
Mode: "Trace width" filter ON
229
d
E5
h
Mode: "Trace width" filter OFF
230
d
E6
h
Mode: "Minimum contrast" filter ON
231
d
E7
h
Mode: "Minimum contrast" filter OFF
232
d
E8
h
Mode: "Trace amplitude" filter ON
233
d
E9
h
Mode: "Trace amplitude" filter OFF
234
d
EA
h
Delete angle compensation factors
240
d
F0
h
Delete error
242
d
F2
h
Delete error bits / error status