Commissioning
Leuze electronic
OGS 600
54
TNT
35/7-2
4
V
8.1.4.1
Status byte in the process data
The process data status byte is composed of 8 bits which convey a state for each filter and
when the warning threshold for the filter is reached. It is output if a global error is present or
when no trace at all has been detected.
The state is always active if the corresponding bit is set.
Bit 0:
General error
–> Reading out of index 201
Error
Bit 1:
Minimum contrast warning
see chapter 7.6 ""Minimum contrast" filter"
Bit 2:
Trace amplitude warning
see chapter 7.7 ""Trace amplitude" filter"
Bit 3:
Trace width error
see chapter 7.5 ""Trace width" filter"
Bit 4:
Minimum contrast error
see chapter 7.6 ""Minimum contrast" filter"
Bit 5:
Trace amplitude error
see chapter 7.7 ""Trace amplitude" filter"
Bit 6:
Switch active
Bit 7:
No trace detected
–> Check guide trace/background
NOTE
Data for traces (edge positions, contrast) which are declared as invalid by a filter is
never