Technical data
Leuze electronic
MSI-MD-FBX
41
13
Technical data
13.1
General specifications
Tab. 13.1:
Safety-relevant technical data
Performance Level (PL)
PL e, Cat. 4 in accordance with EN ISO 13849
Safety Integrity Level (SIL)
SIL 3 in accordance with IEC 61508
SIL Claim Limit (SILCL)
SILCL 3 in accordance with IEC/EN 62061
Probability of a dangerous failure per hour (PFH
d
)
2.5+10E-9
Mission time (T
M
)
20 years
Tab. 13.2:
General system data
Connection technology
M12 connectors, 5-pin, female
M12 connectors, 8-pin, male
Supply voltage U
v
+24 V, ± 20 %, compensation necessary at 20 ms
voltage dip, min. 250 mA (+ external load)
Residual ripple of the supply voltage
± 5 % within the limits of U
v
Current consumption
150 mA (without load)
Protection class
III
Degree of protection
IP 67 acc. to EN 60529
Reaction time
≤ 5 ms
Ambient temperature, operation
-30 … +60 °C
Ambient temperature, storage
-40 … +70 °C
Relative humidity (non-condensing)
0 … 95 %
Vibration resistance
10 - 55 Hz in acc. with IEC/EN 60068-2-6; 0.35 mm
amplitude
Shock resistance
100 m/s
2
acceleration, 16 ms acc. to IEC/
EN 60068-2-6
Dimensions
(L x W x H) 225 mm x 60 mm x 37 mm
Weight
560 g
Maximum length of the connection cable to the ma-
chine interface
50 m
Only permissible with a maximum additional current
demand ≤ 160 mA
Torque for the screws of the cover
0.6 … 0.8 Nm