![Leuze electronic MLD 300 Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/leuze-electronic/mld-300/mld-300_original-operating-instructions_1884028084.webp)
Technical data
Leuze electronic
MLD 300, MLD 500
85
Table 14.4:
System data - transmitter
Table 14.5:
Receiver/transceiver, status signals and control signals
Safety class
III
Protection rating
IP67
Ambient temperature, operation
-30 ... 55 °C
Ambient temperature, storage
-40 ... 75 °C
Relative humidity (non- condensing)
0 ... 95%
Vibration fatigue limit
5 g, 10 - 55 Hz acc. to IEC/EN 60068-2-6;
amplitude 0.35 mm
Shock resistance
10 g, 16 ms in accordance with IEC/EN 60068-
2-6
Profile cross-section
52 mm x 65 mm
Dimensions
See dimensional drawings
Weight
see table 14.8
Transmitter diodes, class acc. to EN 60825-1: 1994 +
A1: 2002 + A2: 2001
1
Wavelength
850 nm
Pulse duration
21.6
ms
Pulse pause
800
ms
Power
Mean power: 1.369
m
W
Voltage output, only for command devices or safety
sensor
RES
Input:
Output:
+24 V
+24 V
PM
a)
/EDM
Input:
+24 V: 10 mA
MODE
Input:
Contact or transistor against
+24 V: 5 mA (pnp)
M-EN/TO
b)
Input:
+24 V: 5 mA
MS1, MS2
Input:
+24 V: 5 mA
a) PM ... partial muting
b) M-EN/TO ... muting-enable/muting timeout