Electrical connection
Leuze electronic
MLD 300, MLD 500
53
Table 7.6:
MLD 330, MLD 530 configuration
The desired muting operating mode is selected via pins 2 and 7 (supply voltage) as well as via a bridge
between pin 1 and another pin.
Functions
Operating mode selection
Op
erating mode
RE
S
EDM
, selecta
ble
Muting type
Muting timeo
ut
Muting timeo
ut exten
sion, selecta
ble: M-T/EN/par
t
Muting-
enab
le
, selectable
Partial muting
, s
electable
Plug pin 2
Plug pin 7
Plug pin 1
1
Timing controlled 2-sen
-
sor muting
10 min
+24 V 0 V
Bridge to pin 4
2
Timing controlled 2-sen
-
sor muting
8 h
+24 V 0 V
Bridge to pin 8
3
Sequence controlled 2-
sensor muting
10 min
0 V
+24 V Bridge to pin 8
4
Sequence controlled 2-
sensor muting
8 h
+24 V 0 V
Bridge to pin 3
5
Timing controlled 2-sen
-
sor muting
10 min
0 V
+24 V Bridge to pin 4
6
Timing controlled 2-sen
-
sor muting
10 min
0 V
+24 V Bridge to pin 3