Mounting
Leuze electronic
MLD 300, MLD 500
34
Calculation of safety distance S
RO
when the height of the upper beam has changed:
The height of the upper beam is now 900 mm. All other parameters remain the same. C
RO
= 1050 mm see
table 6.2.
K
[mm/s]
= 1600 mm/s
T
[ms]
= 335 ms
C
RO
[mm]
= 1050 mm
S
[mm]
= 1600 mm/s × 0.335 s + 1050 mm
S
RO
[mm]
= 1586 mm
This means S
RO
> S, so S
RO
is to be used!
6.1.5 Minimum distance to reflective surfaces
WARNING
Failure to maintain minimum distances to reflective surfaces may result in serious injury!
Reflective surfaces can indirectly deflect the transmitter beams to the receiver. In this case, interruption
of the protective field is not detected.
Determine the minimum distance a see figure 6.3.
Make certain that all reflective surfaces are the necessary minimum distance away from the protective
field see figure 6.4and see figure 6.5.
a
Required minimum distance to reflective surfaces [mm]
b
Protective field width [m]
c
Reflective surface
Figure 6.3: Minimum distance to reflective surfaces depending on protective field width
a
Required minimum distance to reflective surfaces [mm]
b
Protective field width [m]
Figure 6.4: Minimum distance to reflective surfaces as a function of the protective field width up to 10 m
a
b
4°
4°
c
a
900
200
800
300
400
600
500
700
3
5