Diagnostics and troubleshooting
If problems should occur during commissioning of the MA 248
i
you can refer to the following
table. Typical errors and their possible causes are described here as well as tips for their
elimination.
13.1
General causes of errors
Error
Possible error causes
Measures
Data loss
(DL bit)
Data telegram longer than the bus
telegram in bus cycle/memory size.
Increase in bus telegram length.
Toggle out data earlier.
Data in the RS 232
instead of in the
buffer
Incorrect order.
Correct order:
Provide data, toggle CTB.
PWR
status LED on the circuit board
Off
No supply voltage connected to the device. Check supply voltage.
Hardware error.
Send the device to customer service.
Green/orange,
flashing
Device in boot mode.
No valid firmware, send device to cus-
tomer service.
Continuous orange
light
Device error.
Send the device to customer service.
Firmware update failed.
SF
LED on the housing
Green, flashing
Device in service mode.
Reset service mode with webConfig tool.
Red continuous light Network error.
Check interface.
Cannot be rectified by a reset.
Send the device to customer service.
BF
LED on the housing
Red continuous light
Communication error on the PROFINET-IO:
No communication to IO Controller estab-
lished ("no data exchange").
Check interface.
Cannot be rectified by a reset.
Send the device to customer service.
Table 13.1:
General causes of errors