PROFINET
Leuze electronic
DDLS 548i
53
Warning/ Er-
ror
Address
Data type
Value range
Default
Unit
Explanation
Received sig-
nal level in-
tensity (ATT)
1.0
Bit
0: No warning
1:Warning
0
---
Warning in event of
critical received signal
level
Temperature
warning
(TMP/W)
1.1
Bit
0: No warning
1:Warning
0
---
Warning upon exceed-
ing the critical tempera-
ture
Temperature
error (TMP/E)
1.2
Bit
0: No error
1: Error
0
---
Error message upon
exceeding the critical
temperature
Laser pre-
failure mes-
sage (LSR)
1.3
Bit
0: No warning
1:Warning
0
---
Laser pre-failure mes-
sage
Hardware er-
ror
1.4
Bit
0: No error
1: Error
0
---
Error message in event
of hardware defects
Output data
Address
Data type
Value range
Default
Unit
Explanation
Transmission
diode
0.0
Bit
0 … 1
0
---
Switch transmitter
diode on/off
0 -> 1: Transmitter
diode off
1 -> 0: Transmitter
diode on
Operating
mode activa-
tion
0.1
Bit
0 … 1
0
---
Toggle bit for accepting
the selected operating
mode (see following
bits)
0 -> 1: Activation
1 -> 0: Activation
Operating
mode
0.2
…
0.3
Bit Area
0 … 1
0
---
0: Automatic mode
1: LAS mode; switch
on alignment laser
2: LLC mode; switch
on Link Loss Counter
3: Invalid value, is ig-
nored
0.4
Bit
0
---
Free
0.5
Bit
0
---
Free
0.6
Bit
0
---
Free
0.7
Bit
0
---
Free