Device description
Leuze electronic
DDLS 548i
15
4
5
1
2
6
3
1
AUT – Automatic
2
MAN – Manual
3
ADJ – Adjust
4
LAS – Alignment laser for mounting support
5
LLC – Link Loss Counter
6
MODE – Operating mode selector switch
Fig. 3.3:
Operating mode LEDs and operating mode selector switch
Tab. 3.1:
Meaning of the operating mode indicators
LED
Color
State
Description
AUT
Green
Continuous light
AUT operating mode (Automatic) active
Standard operating mode for data transmission
Note:
The optical link remains activated until the last orange LED
in the SIGNAL QUALITY indicator switches off.
MAN
Green
Continuous light
MAN operating mode (Manual) active
Operating mode for fine adjustment of the devices via SHA
(see chapter 6.2.2 "Fine adjustment with the single-handed
adjustment (SHA) process").
Note
:
The optical link remains activated until the last green LED in
the SIGNAL QUALITY indicator switches off.
ADJ
Green
Continuous light
ADJ operating mode (Adjust) active
Operating mode for fine adjustment of the devices via SHA
(see chapter 6.2.2 "Fine adjustment with the single-handed
adjustment (SHA) process").
Note
:
• Data transmission to the connected participants is de-
activated.
• The optical link remains activated until the last orange
LED in the SIGNAL QUALITY indicator switches off.
• The received signal level (SIGNAL QUALITY) of the
second device is transmitted to the SIGNAL QUALITY
indicator of the first device.
LAS
Green
Continuous light
LAS operating mode (Laser Adjustment System) active
The alignment laser mounting support is activated (see