Starting up the device
Leuze electronic
DDLS 548i
41
6
Starting up the device
6.1
Setting the operating mode
The active operating mode is displayed on the control panel to the left next to the operating mode selector
switch [MODE] via LEDs (see chapter 3.3.1 "Indicators and operational controls in the control panel").
4
5
1
2
6
3
1
AUT – Automatic
2
MAN – Manual
3
ADJ – Adjust
4
LAS – Alignment laser for mounting support
5
LLC – Link Loss Counter
6
MODE – Operating mode selector switch
Fig. 6.1:
Operating mode selector switch and operating mode LEDs
The operating mode selector switch [MODE] is used to switch between the operating modes of the device:
Tab. 6.1:
Operating modes
Operating mode Description
AUT
Automatic
Standard operating mode for data transmission. When the supply voltage is applied,
the device starts in the AUT operating mode.
Note:
Operating modes that were active before the device was switched off are no longer ac-
tive after the device is switched back on.
MAN
Manual
Operating mode for fine adjustment of the devices via SHA (see chapter 6.2.2 "Fine
adjustment with the single-handed adjustment (SHA) process").
Data transmission switches off as soon as no green LEDs in the SIGNAL QUALITY in-
dicator illuminate.
Note:
The AUT LED switches off if the MAN operating mode is activated.
ADJ
Aligning
(Adjust)
Operating mode for fine adjustment of the devices via SHA (see chapter 6.2.2 "Fine
adjustment with the single-handed adjustment (SHA) process").
• Data transmission to the connected participants is interrupted.
• The received signal level (SIGNAL QUALITY indicator) of the second device is
transmitted to the SIGNAL QUALITY indicator of the first device.
The quality of the fine adjustment is read directly on the device (SIGNAL QUALITY
indicator) on which the fine adjustment is performed via the alignment screws.
Notes
:
• The AUT LED switches off if the ADJ operating mode is activated.
• The MAN LED switches off if the ADJ operating mode is activated.