Leuze electronic webConfig tool – Extended configuration
Leuze electronic
BPS 307i
66
Configuration of the resolution for position and speed measurement on the SSI interface (
OUTPUT
tab,
Preparation > SSI
)
Figure 9.7: webConfig function
OUTPUT > Preparation > SSI
• Position resolution
Resolution for the position value
• Speed resolution
Resolution for the speed value
Configuration of the bar code tape selection and tape value correction (
MEASUREMENT DATA
tab,
Bar
code tape
)
• Bar code tape with 30 mm grid or 40 mm grid
• Tape value correction
With this parameter, the deviation of the BCB from the correct millimeter scaling that arises from the
production process can be corrected.
Configuration of position detection (
DATA PROCESSING
tab,
Position
>
Detection
)
• Integration depth
Number of successive measurements that the BPS uses for position determination.
• Scaling free resolution
Free scaling of the output of the position values.
• Preset
A preset position value (preset value) is activated at an appropriate position.
• Offset
Output value=measurement value+offset
If a preset is active, this has priority over the offset.
• Error handling procedures
Parameters for the position value in case of failure.