Electrical connection
Leuze electronic
BPS 307i
45
1
3x cable bushing, M16 x 1.5
2
SERVICE: Mini-B USB socket (behind protective cap)
Figure 7.2: Connection hood MK 307, connections
Connect connection PWR / SW IN/OUT to the supply voltage or the switching inputs/outputs.
Connect connection SSI (HOST / BUS IN) to your SSI interface.
7.4
KB 307 connection hood with cable
Connection hood KB 307 features an SSI connection cable and a Mini-B type USB socket as service inter
-
face.
1
SERVICE: Mini-B USB socket (behind protective cap)
2
Connection cable
Figure 7.3: Connection hood KB 307-3000
NOTICE
Cable fabrication!
We recommend against using wire-end sleeves.
NOTICE
Functional earth connection!
Ensure that the functional earth (FE) is connected correctly. Unimpaired operation is only guaranteed
when the functional earth is connected properly. All electrical disturbances (EMC couplings) are dis
-
charged via the functional earth connection.