Leuze electronic webConfig tool – Extended configuration
Leuze electronic
BPS 307i
62
Figure 9.3: webConfig function
OUTPUT
>
HOST formatting
SSI parameters
• Data encoding
Toggling the measurement value encoding: Gray or binary
For devices with connection hood MK 307 or MS 307, the measurement value encoding set here is
overwritten on device startup with the measurement value encoding set via slide switch S1; see
• Position value
Number of data bits - position value
• Speed value
Number of data bits - speed value
• Sign
If changed to
sign with magnitude
, the BPS can also transmit negative position and speed values.
Formatting data output on the SSI interface
To format the data output, the symbols of the configured output modules are arranged in the desired order
in the
SSI formatting
area.
Select the required output module in the
Output modules
area.
Click the symbol for the output module with the left mouse button and keep the mouse button pressed
down.
Drag the symbol for the output module into the white field in the
SSI formatting
area and release the
mouse button (“drag and drop”).
Use “drag and drop” to drag the symbols for all required output modules into the
SSI formatting
area.
Arrange the symbols for the output modules in the
SSI formatting
area with the left mouse button in the
sequence required for the data output.
Save the SSI formatting in the device.
Click the
symbol.