Leuze electronic webConfig tool – Extended configuration
Leuze electronic
BPS 301i
63
Configuration of position detection (
DATA PROCESSING
tab,
Position
>
Detection
)
• Integration depth
Number of successive measurements that the BPS uses for position determination.
• Scaling free resolution
Free scaling of the output of the position values.
• Preset
A preset position value (preset value) is activated at an appropriate position.
• Offset
Output value=measurement value+offset
If a preset is active, this has priority over the offset.
• Error handling procedures
Parameters for the position value in case of failure.
Configuration of position monitoring (
DATA PROCESSING
tab,
Position
>
Monitoring
)
• Position limit value 1/2
Signals that the position value is outside of the configured limit value range.
Configuration of speed detection (
DATA PROCESSING
tab,
Speed
>
Detection
)
• Speed measurement averaging
Measurement value preparation averages all speed values calculated during the selected period
(averaging) to yield a speed output value.
• Scaling free resolution
Free scaling of the output of the speed values.
• Error handling procedures
Parameters for the speed value in case of failure.
Configuration of speed monitoring (
DATA PROCESSING
tab,
Measurement data
>
Speed
>
Monitoring
)
• Speed limit value 1-4
Signals that the speed is outside of the configured limit value range.
Configuration of the measurement value display (
DATA PROCESSING
tab,
General preparation
)
Unit of measurement: metric or inch
• Counting direction
Count direction for position calculation or sign for speed calculation.
• Output mode sign
Output mode of the sign. Affects position value and speed output.
Configuration of monitoring of the reading quality (
DATA PROCESSING
tab,
Reading quality
)
• Warning threshold for reading quality in %
• Error threshold for reading quality in %
Configuration of the communication data (
COMMUNICATION
tab)
• Configuration of the SERVICE USB interface
• Setting the process interface
• Baud rate: 4,800 baud … 115,200 baud
• Data format: 8N1, 8E1, 8O1, 8N2
9.3.3
ALIGNMENT
function
NOTICE
ALIGNMENT
function only in the
Service
operating mode!
The BPS can only be aligned using the
ALIGNMENT
function in the
Service
operating mode.