Leuze electronic webConfig tool – Extended configuration
Leuze electronic
BPS 301i
59
9.3
Short description of the webConfig tool
9.3.1 Overview
Operating modes
For configurations with the webConfig tool, you can switch between the following operating modes:
•
Process
The BPS is connected to the control.
• The process communication to the control is activated.
• The switching inputs/outputs are activated.
• The configuration cannot be changed.
•
PROCESS
function available.
•
ALIGNMENT
function not available.
•
Service
• The process communication to the control is interrupted.
• The switching inputs/outputs are deactivated.
• The configuration can be changed.
•
PROCESS
function not available.
•
ALIGNMENT
function available.
Functions
In the
Process
operating mode, the webConfig tool has the following main menus and functions:
•
HOME
Information on the connected BPS as well as on installation.
This information corresponds to the information in the current technical description.
•
CONFIGURATION
Information on the current BPS configuration – no change to the configuration:
• Display of the interface parameters
• Selection of the used bar code tape (30 mm grid or 40 mm grid)
• Display of the tape value correction (deviation of the BCB from scaling)
• Display of the device components (switching inputs/outputs, display)
• Data processing (position / speed detection or monitoring, data preparation)
• Display of the warning threshold and the error threshold for the reading quality
•
PROCESS
Check and save the current read data in process mode (see chapter 9.3.4).
• Tabular display of the following values:
Scan number, position, speed, reading quality, distance from BCB, info on the control label
In the
Service
operating mode, the webConfig tool also has the following main menus and functions:
•
CONFIGURATION
• Configuration of the interface parameters
• Configuration of device components (switching inputs/outputs, display)
• Selection of the used bar code tape
• Configuration of the data processing (position / speed detection or monitoring, data preparation)
• Configuration of the warning threshold and the error threshold for the reading quality
•
ALIGNMENT
• Display of the following values:
Scan number, position, speed, quality, distance, number of labels in the scanning beam
• Graphical displays of the following values:
Position, speed, quality
•
DIAGNOSIS
• Event logging of warnings and errors.
•
MAINTENANCE
• Firmware update