Operation
Leuze
electronic
96
Technical Description BCL 90
Leuze electronic
8
Operation
8.1
Overview of the Commissioning Steps
• Commissioning the BCL with factory default setting (quick-start).
In this configuration, the BCL can be operated without connecting it to a PC.
• Configuration (parameterization) of the BCL for application with BCL-Config or command strings
8.2
Base Setting
Table 8.1 and Table 8.2 show an overview of the factory default setting of the BCL. The parameters
of the base setting are selected in such a way that the BCL can be used in this configuration directly
or only with small adjustments in many applications. A PC is not needed for commissioning with the
base setting
The base setting values are permanently stored both in the BCL (ROM) and in the database of BCL-
Setup. They can be downloaded any time in the operating memory (RAM) of the BCL or displayed in
the tabs of BCL-Config.
8.2.1 Base Setting of the Line Scanner BCL 90 (All Models)
Parameter
Base setting
Decoder
CRT decoder
Active code types
Codabar, Code 39, 2/5 Interleaved, Code 128
Code length
unlimited (2/5 Interleaved: interval 4 … 50 characters)
Start/stop conditions
automatically
Min./ max.
code position
5/ 95 CP
Multiple reading
3
Min./ max. number of codes 1
Scanning frequency
800 Hz
Autofocus mode
smallest distance
- Range
400 … 2200 mm
- Scanning angle
-30° … +30°
- Focus position switching
trigger
autofocus, immediate/synchronous switching
Reading cycle source
start: switched input "SE 1" (active: high); end: switched input "SE 1"
Switched inputs
SE 2 … SE 6
without autofocus function
Switched input "SE 1"
start and stop of the reading cycle (level: active high), debouncing
20 … 30 ms
Switched outputs
not inverted; pulse duration: 100 ms
- Status output function
SWO 1: "Device Ready" (statical); SWO 2: "Good Read";
SWO 3: "No Read"; SWO 4: "Match 1"
Arrangement to the host
stand alone
Device number
1
Start option
download parameter set from the external parameter memory
Table 8.1: Excerpt: base setting of the parameter values of the BCL 90