![Leuze electronic BCL 90 Скачать руководство пользователя страница 92](http://html.mh-extra.com/html/leuze-electronic/bcl-90/bcl-90_technical-description_1883915092.webp)
Electrical Connection
Leuze
electronic
92
Technical Description BCL 90
Leuze electronic
Table 7.16:Pin and terminal assignment of the switched inputs "SE 2 … SE 6"
• Connect the sensors as shown in Figure 7.5.
Table 7.17:Characteristics of the switched inputs "SE 2 … SE 6"
Input (SE X)
BCL "I/O" connection (pin Y)
SE 2
Pin 6
SE 3
Pin 2
SE 4
Pin 7
SE 5
Pin 11
SE 6
Pin 12
Notice!
For the connection of the switched output via the connector unit MA 90 see data sheet MA
90.
Function
Trigger for focus position switching
SE 5 alternatively:
- trigger for one-shot of the oscillating mirror
SE 6 alternatively:
- trigger for one-shot of the oscillating mirror
- band increment input
Base setting SE 5 and SE 6: focus position switching
Switching characteristics
Active when input is high
Features
- with opto-coupler, polarity-proof
- can be connected to the p-n-p output of a sensor
Electrical values
Low: -30 V
U
e
+2 V
High: +7 V
U
e
+13 V
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]