Electrical connection:
Core cross-section
The required core cross-section of the connection cable for the supply voltage must be at least
0.75 mm². (Also see Section 7.4.2, on page 83)
Power consumption
The energy requirement depends on the model:
• the line scanner with heater typically consumes 75 W and a maximum of 90 W power.
• the line scanner with oscillating mirror and integrated heater typically consumes 75 W and a maxi-
mum of 100 W power.
These values apply to operation with unconnected switched outputs.
Outdoor application:
If the BCL with integrated heater is to be operated outdoors, we recommend installing the BCL in an
additional protective housing. This would prevent the front cover becoming dirty with rain, snow or
dust. At the same time, the housing would serve as protection against wind.
3.1.5 Networking
Up to 31 scanners can be networked via the connector unit MA 90 and a bus master MA 31. For this,
every BCL 90 is assigned its own hardware address in the corresponding MA 90. The networking is
carried out through a parallel connection of the individual RS 485 interfaces.
multiNet plus
In the Leuze proprietary multiNet plus, the bus nodes transmit their data one after the other upon re-
quest by the network master MA 31. In addition, every bus node declared a slave receives a device
address which is adjusted in the corresponding MA 90 via a coding switch. The device address re-
mains in the MA 90 when the scanner is replaced. The master then transmits the data of all bus nodes
via its host interface to a primary PLC control or a computer, i.e. it "collects" the scanner data in the
network and transmits them via an interface to the host computer. This reduces interface costs (CPs)
and time spent programming the software.