Commi
ss
ionin
g
and confi
g
uration
142
BCL
3
04
i
Le
u
ze electronic
Parameter length
2
3
b
yte
Input data
None
Output data
None
Comp
a
r
a
tive
v
a
l
u
e
(Event Co
u
n-
ter)
If the n
u
m
b
er of
a
ctiv
a
tion
event
s
of the
s
elected
s
witch-
on f
u
nction re
a
che
s
thi
s
com-
p
a
r
a
tive v
a
l
u
e, the
s
witching
o
u
tp
u
t i
s
a
ctiv
a
ted. A de
a
ctiv
a
-
tion event of the
s
elected
s
witch-off f
u
nction re
s
et
s
the
co
u
nter.
9
UN
S
IGNED16
0..655
3
5
0
-
Comp
a
re
mode
(Event Co
u
n-
ter)
S
pecifie
s
whether the
s
witch-
ing o
u
tp
u
t
s
witche
s
only on
p
a
rity (once) or
a
l
s
o in the
event of gre
a
ter or eq
ua
l to
(m
u
ltiple time
s
)
a
fter the com-
p
a
r
a
tive v
a
l
u
e i
s
re
a
ched.
11
UN
S
IGNED
8
0:
S
WOUT
s
witche
s
once
1:
S
WOUT
s
witche
s
s
ever
a
l
time
s
0
-
Re
s
et mode
(Event Co
u
n-
ter)
S
pecifie
s
whether the co
u
nter
(Event Co
u
nter) i
s
re
s
et only
b
y the re
s
et
b
it
a
nd the
s
elected
s
witch-off f
u
nction, or
if the co
u
nter
s
ho
u
ld
b
e
au
to-
m
a
tic
a
lly re
s
et
a
fter the com-
p
a
r
a
tive v
a
l
u
e i
s
re
a
ched.
12
UN
S
IGNED
8
0: Re
s
et
b
it
a
nd
s
witch-
off f
u
nct.
1: Comp
a
r
a
-
tive v
a
l
u
e
re
a
ched
0
-
Mode of operation for confi
g
uration a
s
an input
Inver
s
ion
The p
a
r
a
meter define
s
the
logic of the incident
s
ign
a
l. In
c
as
e of
a
n inver
s
ion,
a
n exter-
n
a
l HIGH level i
s
interpreted
intern
a
lly
as
a
LOW level.
1
3
.1
Bit
0: Norm
a
l
1: Inverted
0
-
Re
s
erved
Free
1
3
.2 … 1
3
.7
De
b
o
u
nce
time
The p
a
r
a
meter define
s
a
de
b
o
u
nce time which i
s
imple-
mented in
s
oftw
a
re.
14
UN
S
IGNED16
0 … 1000 5
m
s
S
t
a
rt-
u
p del
a
y
The p
a
r
a
meter infl
u
ence
s
the
timing d
u
ring
s
witch-on.
16
UN
S
IGNED16
0 … 655
3
5
0
m
s
Minim
u
m
s
witch-on
time
The p
a
r
a
meter define
s
a
mini-
m
u
m time period
b
efore the
s
ign
a
l i
s
re
s
et.
1
8
UN
S
IGNED16
0 … 655
3
5
0
m
s
S
witch-off
del
a
y
The p
a
r
a
meter define
s
a
time
del
a
y for the
s
ign
a
l d
u
ring
s
witch-off.
20
UN
S
IGNED16
0 … 655
3
5
0
m
s
Inp
u
t f
u
nction
The p
a
r
a
meter
s
pecifie
s
the
f
u
nction which i
s
to
b
e
a
cti-
v
a
ted or de
a
ctiv
a
ted
b
y
a
ch
a
nge of
s
t
a
te in the
s
ign
a
l.
22
UN
S
IGNED
8
cf. "Inp
u
t f
u
nc-
tion
s
" on
p
a
ge 141
1
-
Parameter
De
s
cription
Addr.
Data type
Value ran
g
e
Default
Unit
T
ab
le 10.46:
P
a
r
a
meter
s
for mod
u
le 70 – Inp