Commi
ss
ionin
g
and confi
g
uration
Le
u
ze electronic
BCL
3
04
i
93
TNT
35/7-2
4
V
10.4.3
General information on the G
S
D file
Yo
u
c
a
n find the G
S
D file
a
t
www.leuze.com -> Download -> identify ->
S
tationary and hand-held bar code reader
s
.
All d
a
t
a
in mod
u
le
s
req
u
ired for oper
a
ting the
BCL 304
i
i
s
de
s
cri
b
ed in thi
s
file. The
s
e
a
re
inp
u
t
a
nd o
u
tp
u
t d
a
t
a
a
nd device p
a
r
a
meter
s
for the f
u
nctioning of the
BCL 304
i
a
nd the
definition of the control
a
nd
s
t
a
t
us
b
it
s
.
If p
a
r
a
meter
s
a
re ch
a
nged, e.g., in the project tool, the
s
e ch
a
nge
s
a
re
s
tored on the PLC
s
ide in the project, not in the G
S
D file. The G
S
D file i
s
a
certified
a
nd integr
a
l p
a
rt of the
device
a
nd m
us
t not
b
e ch
a
nged m
a
n
ua
lly. The file i
s
not ch
a
nged
b
y the
s
y
s
tem either.
The f
u
nction
a
lity of the
BCL 304
i
i
s
defined vi
a
G
S
D p
a
r
a
meter
s
et
s
. The p
a
r
a
meter
s
a
nd
their f
u
nction
s
a
re
s
tr
u
ct
u
red in the G
S
D file
us
ing mod
u
le. A
us
er-
s
pecific config
u
r
a
tion tool
i
s
us
ed d
u
ring PLC progr
a
m cre
a
tion to integr
a
te the req
u
ired mod
u
le
s
a
nd config
u
re them
a
ppropri
a
tely for their re
s
pective
us
e. D
u
ring oper
a
tion of the
BCL 304
i
on the PROFIBU
S
,
a
ll p
a
r
a
meter
s
a
re
s
et to def
au
lt v
a
l
u
e
s
. If the
s
e p
a
r
a
meter
s
a
re not ch
a
nged
b
y the
us
er,
the device f
u
nction
s
with the def
au
lt
s
etting
s
delivered
b
y Le
u
ze electronic.
For the def
au
lt
s
etting
s
of the
BCL 304
i
, ple
as
e refer to the following mod
u
le de
s
cription
s
.
Notice!
Please note that the set data is overwritten by the PLC!
Some controls make available a so-called "universal module". This module must not be
activated for the
BCL 304
i
!
From the per
s
pective of the device,
a
di
s
tinction i
s
m
a
de
b
etween PROFIBU
S
p
a
r
a
meter
s
a
nd intern
a
l p
a
r
a
meter
s
. PROFIBU
S
p
a
r
a
meter
s
a
re
a
ll p
a
r
a
meter
s
th
a
t c
a
n
b
e ch
a
nged vi
a
the PROFIBU
S
a
nd
a
re de
s
cri
b
ed in the following mod
u
le
s
. Intern
a
l p
a
r
a
meter
s
, on the
other h
a
nd, c
a
n only
b
e ch
a
nged vi
a
a
s
ervice interf
a
ce
a
nd ret
a
in their v
a
l
u
e even following
a
PROFIBU
S
config
u
r
a
tion.
D
u
ring the config
u
r
a
tion ph
as
e, the BCL receive
s
a
p
a
r
a
meter telegr
a
m from the m
as
ter.
Before thi
s
i
s
ev
a
l
ua
ted
a
nd the re
s
pective p
a
r
a
meter v
a
l
u
e
s
a
re
s
et,
a
ll PROFIBU
S
p
a
r
a
meter
s
a
re re
s
et to def
au
lt v
a
l
u
e
s
. Thi
s
en
su
re
s
th
a
t the p
a
r
a
meter
s
of mod
u
le
s
th
a
t
a
re
not
s
elected
a
re
s
et to the def
au
lt v
a
l
u
e
s
.
Notice!
This does not affect modules 1-4 for the code table extension. By default, all but the first
code table entry are locked. If "no code" is selected here, all subsequent code tables are
deactivated (see chapter 10.6.1 "Modules 1-4 – Code table extensions 1 to 4").
Содержание BCL 300 Series
Страница 1: ...BCL304i Bar code reader en 01 10 2011 50117112 T E C H N I C A L D E S C R I P T I O N ...
Страница 61: ...Installation and mounting 68 BCL 304i Leuze electronic Figure 6 4 Mounting example of BCL 304i with BT 56 ...
Страница 173: ...Appendix 146 BCL 304i Leuze electronic Figure 15 2 Connection hood connector unit declaration of conformity ...