Commi
ss
ionin
g
and confi
g
uration
Le
u
ze electronic
BCL
3
04
i
107
TNT
35/7-2
4
V
10.7.2
Module 11 – Readin
g
g
ate control
Description
With the mod
u
le, the re
a
ding g
a
te control of the
ba
r code re
a
der c
a
n
b
e
a
d
a
pted to the
a
ppli-
c
a
tion. With different p
a
r
a
meter
s
from the
ba
r code re
a
der,
a
time-controlled re
a
ding g
a
te
m
a
y
b
e cre
a
ted. In
a
ddition, it define
s
the intern
a
l criteri
a
for the re
a
ding g
a
te end
a
nd the
completene
ss
in
s
pection.
Parameter
Parameter
De
s
cription
Addr.
Data type
Value ran
g
e
Default
Unit
A
u
tom
a
tic
re
a
ding g
a
te
repe
a
t
The p
a
r
a
meter define
s
the
au
tom
a
tic repe
a
t
of re
a
ding g
a
te
s
.
0
Byte
0: No
1: Ye
s
0
-
Re
a
ding g
a
te
end mode/
complete-
ne
ss
mode
Thi
s
p
a
r
a
meter c
a
n
b
e
us
ed to config
u
re the
completene
ss
in
s
pec-
tion.
1
Byte
0:
Independent of decodin
g
,
i.e., the re
a
ding g
a
te i
s
not ter-
min
a
ted prem
a
t
u
rely.
1:
Dependent on decodin
g
, i.e,
the re
a
ding g
a
te i
s
termin
a
ted
if the config
u
red n
u
m
b
er of
ba
r code
s
to
b
e decoded h
as
b
een re
a
ched.
1)
2:
Di
g
itRef table-dependent
,
i.e., the re
a
ding g
a
te i
s
termi-
n
a
ted if e
a
ch
ba
r code
s
tored
in the code type t
ab
le h
as
b
een decoded.
2)
3
:
Ident li
s
t dependent
, i.e., the
re
a
ding g
a
te i
s
termin
a
ted if
e
a
ch identifier
s
tored in
a
li
s
t
co
u
ld
b
e
s
egmented vi
a
a
re
s
pective
ba
r code
s
egmen-
t
a
tion.
3
)
4:
Reference code compari-
s
on
, i.e., the re
a
ding g
a
te i
s
termin
a
ted if
a
po
s
itive refer-
ence code comp
a
ri
s
on h
as
t
a
ken pl
a
ce.
4)
1
-
Re
s
t
a
rt del
a
y
The p
a
r
a
meter
s
peci-
fie
s
a
time
a
fter which
a
re
a
ding g
a
te i
s
re
s
t
a
rted. The
BCL
3
04
i
gener
a
te
s
it
s
own periodic re
a
d-
ing g
a
te.
The config
u
red time i
s
a
ctive only if the
au
to-
m
a
tic re
a
ding g
a
te
repe
a
t i
s
s
witched on.
2
UN
S
IGNED16
0 … 655
3
5
0
m
s
M
a
x. re
a
ding
g
a
te time
when
s
c
a
nning
The p
a
r
a
meter
s
witche
s
off the re
a
d-
ing g
a
te
a
fter the
s
et
time h
as
el
a
p
s
ed, th
us
limiting the re
a
ding
g
a
te to the
s
et period.
4
UN
S
IGNED16
1 … 655
3
5
0: Re
a
ding g
a
te de
a
ctiv
a
tion i
s
s
witched off.
0
m
s
T
ab
le 10.12:
P
a
r
a
meter
s
for mod
u
le 11
Содержание BCL 300 Series
Страница 1: ...BCL304i Bar code reader en 01 10 2011 50117112 T E C H N I C A L D E S C R I P T I O N ...
Страница 61: ...Installation and mounting 68 BCL 304i Leuze electronic Figure 6 4 Mounting example of BCL 304i with BT 56 ...
Страница 173: ...Appendix 146 BCL 304i Leuze electronic Figure 15 2 Connection hood connector unit declaration of conformity ...