Commissioning
Leuze electronic
Technical description BCL 21/22 SB
47
TNT
35/7-2
4
V
Notice!
From the hardware address, the BCL 21 detects that networking is required. With the
BCL 21/22, it is possible to perform a reset using the software and the online commands.
In addition, it is possible to perform a reset by switching off the supply voltage. The param-
eters are not lost as a result of the reset. For information on the reset commands, see
chapter 9. The LED remains dark during a reset; the green LED illuminates when the device
is ready for operation.
7.2
Function Test
"Power On" test
After connecting the operating voltage, the devices carry out an automatic "Power On"
function test. The LED on the front side of the MA 2/MA 4…/MA 2xxi lights up. In the case
of factory settings, the green LED flashes. In the additional service mode, the orange LED
lights up.
Interface
Proper function of the interface can be tested easiest in service operation using the service
interface with the "BCLConfig" programming software and a notebook computer. For order
numbers, see chapter 5.
"Online commands"
Using the "Online" commands, important device functions can be checked, e.g. proper
functioning of the laser.
Problems
Should problems occur during device commissioning, refer first to chapter 8.2. Should a
problem persist after checking all electrical connections and settings on the devices and
host, please contact a Leuze service office near you (see the back page of this operating
manual).