LEUSCH LTR 43 Series Скачать руководство пользователя страница 7

7

Industrial Valves

Position Indicator and key direction

(Fig. 6)

On versions with a coupling, the disc position is marked
by two red dots. In the closed position, the imaginary
connection axis between the red marks is perpendicular
to the flow direction

Note the key position on versions without coupling.

The valve closes when the drive shaft is rotated clock-
wise (right-turning closure).

Fig. 6

Installing the actuator

See also the instructions for the different actuators.

1.

Turn the disc to the OPEN position to avoid dam-
age to the seat.

2.

Move the actuator to the OPEN position.

3.

Place the actuator in the desired position on the
shaft.

Attention!

 Note the key alignment.

4.

Correctly fasten the actuator to the valve using
the screws.

5.

Adhere to the instructions detailed under
“Maintenance and adjustments” when setting the
limit stops on the actuator.

Содержание LTR 43 Series

Страница 1: ...tor e g pneumatic electrical or hydraulic the following applies Do not put any parts of your body limbs inside the valve when an actuator is in stalled Sudden unexpected moving parts e g through actin...

Страница 2: ...ransport of the valves e g dry storage use of suitable sling materials etc Use of the valves with fluids that the select ed materials are sufficiently resistant to The fluid compatibility of the valve...

Страница 3: ...atal injury if the auxiliary ener gy suddenly fails and the valve disc then moves on its own into the fail safe position as a result of spring decompression For devices equipped with a spring return a...

Страница 4: ...that The valve disc does not collide with the pipeline during opening closing The parts which come into contact with fluid are suitable for the planned usage Actuators and accessories if available ar...

Страница 5: ...f only torque values are required Complete Packing and repair sets for maintenance of the valves are available from LEUSCH or and the authorised LEUSCH representative Before contacting your representa...

Страница 6: ...proce dure 10 Valves which are not actuated for long periods must undergo functional tests on a regular basis If necessary shorter maintenance intervals may be required if increased wear is expected o...

Страница 7: ...the drive shaft is rotated clock wise right turning closure Fig 6 Installing the actuator See also the instructions for the different actuators 1 Turn the disc to the OPEN position to avoid dam age t...

Страница 8: ...5 and washers 56 9 Tighten the nuts 55 alternately by hand using minimal force 10 Install the key 68 11 Put the valve into operation and alternately tighten the nuts 55 in little steps in the event of...

Страница 9: ...ium residues around the cover 1 Loosen and remove the screws 53 Fig 10 2 Disassemble the cover 7 and remove the old cover seal 37 3 The ring 25 may fall out fom the body when the cover is disassembled...

Страница 10: ...rate docu ments If it is necessary to replace the seating elements note the type series from the name plate and re quest the adequate instruction from LEUSCH Industrial Valves It can also be downloade...

Страница 11: ...may be available on additional metal plates Service It is recommended to check the device regularly for external leaks and other adverse effects or anything conspicuous The Gland Packing usually consi...

Страница 12: ...__________________________________________________________ _________________________________________________________________________________________________ ___________________________________________...

Отзывы: