32
PARAMETER-SETTING MANUAL
VARMECA 10
Variable speed motors and geared motors
GENERAL INFORMATION
LEROY-SOMER
Ref. 3264 - 4.33/b -1.00
1.4.2 - Configuration option 1: 2 preset speeds - 2 operating directions
Terminals
Specifications
1
+10 V analogue source
Rated current: 3 mA
2
Analogue input not used
3
Analogue output 0 to +10 V
Rated current: 3 mA
0 V = zero speed
10 V = max. speed
4
0 V - common with terminal 6
5
Logic input S1
6
0 V - common with terminal 4
7
Logic input
run reverse/stop
8
Logic input
run forward/stop
9 - 10
Relay output 250 V - 1A
Switched off or faulty
On
1
2
3
4
5
6
7
9
L1
L2
L3
PE
10
8
Fault
relay
0-10V speed image output
0V
Preset speed selection
S1
0V
Run reverse / stop
Run forward / stop
MAINS
SUPPLY
Associated parameter setting
CDC-VMA
PEGASE VMA 10
Terminal block configuration
P14 = 1
OPTION 1
P15 = VP1-1(Hz)
VP1 OPTION 1(Hz)
P16 = VP2-1(Hz)
VP2 OPTION 1(Hz)
MINI DIP K4 = ON
Reference
S1
VP1-1
1
VP2-1
0
Setting other parameters
see sections 2 and 3