background image

No.

Description

No.

Description

No.

Description

Fixing screw for nos  92 +140

Brush

Fixing screw for fan housing

Fan grille

Lower inspection door

Air flow detector

Fixing screw for grille no. 110

Drive end cover

Fan motor

Fan housing

DE bearing inspection door

Filter (optional)

NDE shield inspection door

Fixing screw for inspection door no. 401

Fixing screw for filter

Fixing screw for no. 140 (opp. terminal box)

Seal for inspection door no. 140

Fixing screw for inspection door no. 159

Brush holder

Seal for door no. 159

Fixing screw for retaining plate no. 52

93

150

407

110

159

408

111

400

409

118

401

410

140

402

411

141

403

413

149

405

420

*: number linked to an option.

403

411

410

118

409

408

407

C

403 

92

403

420

52

62

14

403

141

140

25

28

150

149

6

93

140

75

85

82

84

70

69

413

72

77

74

81

159

60

50

53

405

A

B

LSK
D.C. motors

15.1 - LSK 1122, 1124, 1324 & 1604 (continued)

11

LSK motor model 1122 to 1604

Содержание LSK 1122

Страница 1: ...3 1 26 D C motors D C motors Installation and maintenance Installation and maintenance R f 1744 4 33 c 5 97 LSK...

Страница 2: ...TOOLS 3 2 HANDLING 3 3 LOCATION 3 4 ENVIRONMENT 3 5 COMMISSIONING 3 5 1 Connection 4 6 ELECTRICAL CONNECTION 4 6 1 Thermal detection 4 6 2 Space heaters 5 6 3 Connection diagram 6 3 1 Models 1122 to...

Страница 3: ...handling rings which are located diagonally opposite and are fixed on the DE and NDE motor flanges A lifting bar must be used to avoid damaging the forced ventilation unit on the motor see diagram op...

Страница 4: ...ction by integration of overload 100 of supply current instantaneous protection 200 of supply current protection against ground faults protection against field overvoltages if there is a short circuit...

Страница 5: ...page 82 The motors are connected at the factory when the field voltage is specified in the order Field coils with 4 output terminals and series con nection clockwise rotation seen from the drive end D...

Страница 6: ...hange the direction of motor rotation reverse the field polarity 7 MAINTENANCE See section 5 of the general manual reference 1596 to ensure the motor lasts as long as possible Brushes Warning the foll...

Страница 7: ...at bearings should be replaced whenever the motor is dismantled 10 CLEANING Do not use solvents as they can damage the varnish and protection of windings as well as the commutator Clean the parts care...

Страница 8: ...al position and check the position of labels 1 and 2 10 Tighten screws 3 4 to hold the brush holder in position 11 Tighten the connection cable screws 1 2 12 Run the brushes in following the running i...

Страница 9: ...ed ventilation unit and its direction of rotation Check operation of the machine being driven Premature wear of brushes Operating underload Vibration Possible reduction in ventilation by the FV moving...

Страница 10: ...4 Lifting ring option fitted on rear end shield Cable gland support plate Identification plate NDE bearing retaining plate lubrication Fixing screw for plate no 81 Lifting ring fixing screw option for...

Страница 11: ...screw for filter Fixing screw for no 140 opp terminal box Seal for inspection door no 140 Fixing screw for inspection door no 159 Brush holder Seal for door no 159 Fixing screw for retaining plate no...

Страница 12: ...washer Retainer for motor with no options fitted Fixing screw for plate no 81 Shaft extension screw NDE bearing circlip Terminal block Lifting ring Fixing screw for retainer no 52 and or 160 Terminal...

Страница 13: ...ixing screw for filter Brush Seal for door no 159 Fixing screw for inspection door no 159 Lower inspection door Fixing screw for fan housing Fixing screw for retaining plate no 52 LSK motor models 180...

Страница 14: ...0 130 130 130 114 114 130 130 6 6 LSK 1124 114 114 130 130 130 130 114 114 130 130 6 6 LSK 1324 140 140 160 160 160 160 140 140 160 160 8 8 LSK 1604 135 135 150 150 150 150 175 175 190 190 8 8 LSK 180...

Страница 15: ...s monitoring for wear mm Replace the brushes if required Power up the machine being used Check the commutator is not sparking Stop the motor switch off and replace inspection doors Check that the cool...

Страница 16: ...MOTEURS LEROY SOMER 16015 ANGOUL ME CEDEX FRANCE RCS ANGOUL ME N B 671 820 223 S A au capital de 131 910 700 F http www leroy somer com...

Отзывы: