Function library
Function blocks
3.2.19
Setpoint conditioning (CCTRL)
3−68
l
EDSVS9332K−EXT EN 4.0
Signal
Source
Comment
Name
Type
DIS
DIS format
CFG
List
CCTRL−MRED
a
C1341/2
dec [%]
C1340/2
1
Gain for the torque setpoint precontrol
CCTRL−NRED
a
C1341/1
dec [%]
C1340/1
1
Gain for the speed setpoint precontrol
CCTRL−N2−SET
d
C1343/3
bin
C1342/3
2
HIGH: input CCTRL−NSET2 active
CCTRL−IN
phd
C1347/1
rpm
C1346/1
4
Input for the set profile position
CCTRL−RESET
d
C1343/1
bin
C1342/1
2
HIGH: sets set angle = actual angle −> CCTRL−POUT = 0
CCTRL−Y−END
ph
C1345/1
inc
C1344/1
3
Final value of the profile (only required for touch probe)
CCTRL−NSET2
phd
C1347/2
rpm
C1346/2
4
Input for the second set machine position
CCTRL−RESET−N2
d
C1343/6
bin
C1342/6
2
Deletes the contouring error if CCTRL−N2−Set = HIGH
CCTRL−CLR−INTEG
d
C1343/7
bin
C1342/7
2
HIGH: Sets all integrators to 0
CCTRL−SUB−Y−END
d
C1343/5
bin
C1342/5
2
Only required for touch probe
CCTRL−TP−POS
d
C1345/2
bin
C1324/3
2
Only for synchronisation via touch probe. Position of the touch
probe sensor in the traversing range
CCTRL−TPIN/E4
d
C1343/4
bin
C1342/4
2
HIGH: Touch probe is activated via terminal X5/E4
LOW: Touch probe is activated via CCTRL−TPIN
CCTRL−TPIN
d
C1343/2
bin
C1342/2
2
External mark for setting the position
CCTRL−MOUT
a
1
Torque setpoint for input MCTRL−M−ADD (torque feedforward
control)
CCTRL−NOUT
a
1
Speed setpoint for input MCTRL−N−SET (speed feedforward
control)
CCTRL−DFOUT
phd
4
Speed setpoint
CCTRL−PHI−SET
ph
C1339/1
3
Output of the set machine position
CCTRL−POUT
ph
3
Contouring error, input signal for MCTRL−PHI−SET
CCTRL−PHI−SET2
ph
C1339/2
3
Output of the set machine position of CCTRL−NSET2
CCTRL−PHI−ACT
ph
C1339/3
3
Output of the actual machine position
CCTRL−TP−RECOGN
d
2
Output is HIGH for 1 ms in the case of
a HIGH−LOW edge at terminal X5/E4 or
CCTRL−TPIN/E4 = HIGH
Function
l
Set profile position and second set machine position (
3−68)
l
Homing (
l
Set reference once (
l
Speed feedforward control (
l
Torque feedforward control (
3.2.19.1
Set profile position and second set machine position
At CCTRL−IN, the set profile position is specified. The set machine position is output at
CCTRL−PHI−SET. It is the reference value for controlling the cam.
For auxiliary functions like inching mode, position override function (e. g. approaching cleaning
position) or homing, you can define a second set machine position at CCTRL−PHI−SET2. If a
changeover to the second set machine position is effected, the set machine position at
CCTRL−PHI−SET is maintained and can be approached again after the auxiliary function has been
completed.
Содержание EVS93 Series
Страница 2: ......
Страница 8: ...Preface and general information 1 2 l EDSVS9332K EXT EN 4 0...
Страница 14: ...Preface and general information Definition of the notes used 1 8 l EDSVS9332K EXT EN 4 0...
Страница 16: ...Configuration 2 2 l EDSVS9332K EXT EN 4 0...
Страница 28: ...Configuration Operating modes 2 3 2 Control 2 14 l EDSVS9332K EXT EN 4 0...
Страница 32: ...Function library 3 4 l EDSVS9332K EXT EN 4 0...
Страница 362: ...Application examples 4 2 l EDSVS9332K EXT EN 4 0...
Страница 374: ...Application examples 4 4 Mark controlled cam profile start 4 14 l EDSVS9332K EXT EN 4 0...
Страница 376: ...Appendix 5 2 l EDSVS9332K EXT EN 4 0...
Страница 385: ......