Function library
Function blocks
3.2.26
Signal conversion (CONV)
3−108
l
EDSVS9332K−EXT EN 4.0
3.2.26
Signal conversion (CONV)
Purpose
These function blocks can be used to standardize signals or signal types or to convert signal types
into different signal types.The conversion is very precise by providing the conversion factor as
numerator and denominator.
CONV1
C 0 9 4 2
C 0 9 4 3
C O N V 1 - I N
C O N V 1 - O U T
C O N V 1
C 0 9 4 0
C 0 9 4 1
C O N V 1 - D F O U T
fb_conv1
Fig. 3−78
Function block CONV1
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
CONV1−IN
a
C0943
dec [%]
C0942
1
1000
CONV1−OUT
a
−
−
−
−
−
Limited to ±199.99 %
CONV1−DFOUT
phd
−
−
−
−
−
Limited to ±29999 rpm
This function block is used to multiply or divide analog signals.
CONV1−OUT
+
CONV1−IN
@
100 %
15000 rpm
@
C0940
C0941
or
CONV1−DFOUT
+
CONV1−IN
@
C0940
C0941
[rpm]
Example:
An analog signal is to be multiplied by 1.12.
For this, enter C0940 = 112 and C0941 = 100.
Содержание EVS93 Series
Страница 2: ......
Страница 8: ...Preface and general information 1 2 l EDSVS9332K EXT EN 4 0...
Страница 14: ...Preface and general information Definition of the notes used 1 8 l EDSVS9332K EXT EN 4 0...
Страница 16: ...Configuration 2 2 l EDSVS9332K EXT EN 4 0...
Страница 28: ...Configuration Operating modes 2 3 2 Control 2 14 l EDSVS9332K EXT EN 4 0...
Страница 32: ...Function library 3 4 l EDSVS9332K EXT EN 4 0...
Страница 362: ...Application examples 4 2 l EDSVS9332K EXT EN 4 0...
Страница 374: ...Application examples 4 4 Mark controlled cam profile start 4 14 l EDSVS9332K EXT EN 4 0...
Страница 376: ...Appendix 5 2 l EDSVS9332K EXT EN 4 0...
Страница 385: ......