Function library
Function blocks
3.2.54
Freely assignable input variables (FEVAN)
3−176
l
EDSVS9332K−EXT EN 4.0
Conversion
Conversion at the example of FB FEVAN1.
l
The data format of the target code is important for the conversion (see attribute table).
l
Adapt the input signal to the data format of the target code with:
– C1093 (numerator).
– C1094 (denominator).
l
C1094 also determines the decimal positions of the target code:
– Set C1094 according to the existing decimal positions of the target code. The number of
decimal positions can be obtained from the code table.
– 0.0001
¢
no decimal positions.
– 0.001
¢
one decimal position.
– 0.01
¢
two decimal positions.
– 0.1
¢
three decimal positions.
– 1
¢
four decimal positions.
l
For target codes with % scaling the formula for conversion must include a scaling factor (see
example 1).