Technical data
General data and operating conditions
4
49
EDK10200EV3 DE/EN/FR 7.1
4
Technical data
General data and operating conditions
Field
Values
Conformity
CE
Low−Voltage Directive (2006/95/EC)
Approvals
UL 508C
Underwriter Laboratories (File−No. E132659)
Power Conversion Equipment
DC supply voltage
Voltage
+18 VDC − 0 % ... +30 VDC + 0 %
Current
Max. 4.2 A at 24 VDC:
l
200 mA at +24 V (Drive PLC supply)
l
max. 1A per output at Drive PLC
Note: The outputs of the extension boards must be
supplied externally
Supply conditions
The device must not be connected to voltages > 50 V against PE.
The device must not be used in mains circuits.
Climatic conditions
Class 3K3 to EN 50178
(without condensation, average relative humidity 85 %)
Temperature range
Transport
−25 °C ... +70 °C
Storage
−25 °C ... +60 °C
Operation
0°C ... +40 °C without power derating
+40 °C ... +55 °C with derating
Power derating
Of output currents at t
a
> +40 °C: 2.5 %/K
Vibration resistance
Resistant to acceleration up to 0.7 g
Permissible mounting
positions
Vertical
Free space
³
100 mm below and above
Enclosure
IP 20
Total insulation
The degree of insulation of the device depends on the degree of
insulation of the voltage source and the components connected.