Process data transfer
Lenze device control
Process output data configuration
l
38
EDS82ZAFPC201 EN 4.0
C1511: Configuration of process output data
Code
Subcode
Index
Possible settings
Data type
Lenze
Selection
C1511
23064
d
=
5A18
h
FIX32
1 (POW1)
17
see table below
2 (POW2)
3
3 (POW3)
4
4 (POW4)
5
5 (POW5)
6
6 (POW6)
7
7 (POW7)
8
8 (POW8)
9
9 (POW9)
10
10 (POW10)
11
The assignment of the up to 10 process data output words (POW) of the master to the bit
control commands or controller setpoints can be freely configured.
Selection
Scaling
1
FIF control word 1 (FIF−CTRL1)
16 bits
2
FIF control word 2 (FIF−CTRL2)
16 bits
3
Setpoint 1 (NSET1−N1)
±24000
º
±480 Hz
4
Setpoint 2 (NSET1−N2)
±24000
º
±480 Hz
5
Additional setpoint (PCTRL1−NADD)
±24000
º
±480 Hz
6
Actual process controller value (PCTRL1−ACT)
±24000
º
±480 Hz
7
Process controller setpoint (PCTRL1−SET1)
±24000
º
±480 Hz
8
Reserved
9
Torque setpoint/torque limit value (MCTRL1−MSET)
2
14
º
100 % rated motor torque
10
PWM voltage (MCTRL1−VOLT−ADD)
(
For special applications only.
^
System manual for 8200 vector
11
PWM angle (MCTRL1−PHI−ADD)
12
Reserved
13
FIF−IN.W1
16 bits or 0 ... 65535
14
FIF−IN.W2
16 bits or 0 ... 65535
15
FIF−IN.W3
0 ... 65535
16
FIF−IN.W4
0 ... 65535
17
DRIVECOM control word (DRIVECOM−CTRL)
16 bits
18
Reserved
19
PROFIdrive control word (PROFIdrive−CTRL)
16 bits