Mechanical installation
Notes on mounting the device version in push−through design
Assembly in push−through technique (thermal separation)
l
80
EDS700ACBA EN 5.1
All about cooling
A good cooling is achieved by a focussed air flow at the cooling ribs.
By measuring the air speed, the compliance with the required cooling should be checked.
The measurement has to be executed at the points (MP) defined in the illustration for the
heatsink cross−section.
Fig. 5−3
Positions of the measuring points, centrally above the heatsink
If a single fan is to cool several devices, this fan has to provide the sum of all volume flows.
I
Tip!
An air channel serves to implement a protection against accidental contact
towards the hot heatsink surface.
An air channel provides a sufficient air flow for each device.
Содержание E70AC Series
Страница 1: ...EDS700ACBA Usx Usx Hardware Manual i700 l E70AC Servo Inverter i700 Translation...
Страница 2: ...0Fig 0Tab 0...
Страница 75: ...Mechanical installation 5 l 75 EDS700ACBA EN 5 1...
Страница 147: ...Accessories overview Terminals 11 l 147 EDS700ACBA EN 5 1 E70AZEVK001 i700ZM001 A...
Страница 148: ...Accessories overview Terminals 11 l 148 EDS700ACBA EN 5 1 E70AZEVK002 i700ZM001 C...
Страница 149: ...Accessories overview Terminals 11 l 149 EDS700ACBA EN 5 1 E70AZEVK003 i700ZM001 B...
Страница 150: ...Accessories overview Terminals 11 l 150 EDS700ACBA EN 5 1 E70AZEVK004 i700ZM001 D...
Страница 151: ...Accessories overview Terminals 11 l 151 EDS700ACBA EN 5 1 E70AZEVK005 i700ZP005 a...
Страница 152: ...Accessories overview Terminals 11 l 152 EDS700ACBA EN 5 1 E70AZEVK006 i700ZP005 b...
Страница 157: ...Accessories overview EMC accessories Shield mounting 11 l 157 EDS700ACBA EN 5 1 ezamb_001 EZAMBKBM 10 mm 8 30 mm...
Страница 161: ......