Safety instructions
General safety and application notes for Lenze motors
l
16
EDS700ACBA EN 5.1
Waste disposal
Recycle metal and plastic materials. Assembled PCBs must be disposed of professionally.
The product−specific safety and application notes given in these instructions must be
observed!
2.2
General safety and application notes for Lenze motors
(according to Low−Voltage Directive 2014/35/EU)
General
Low−voltage machines have dangerous, live and rotating parts as well as possibly hot
surfaces.
Synchronous machines induce voltages at open terminals during operation.
All operations serving transport, connection, commissioning and maintenance are to be
carried out by skilled, responsible technical personnel (observe EN 50110−1 (VDE 0105−1)
and IEC 60364). Improper handling can cause severe injuries or damages.
Lowvoltage machines may only be operated under the conditions that are indicated in the
section "Application as directed".
The conditions at the place of installation must comply with the data given on the
nameplate and in the documentation.
Application as directed
Lowvoltage machines are intended for commercial installations. They comply with the
harmonised standards of the series IEC/EN60034 (VDE 0530). Their use in potentially
explosive atmospheres is prohibited unless they are expressly intended for such use
(follow additional instructions).
Lowvoltage machines are components for installation into machines as defined in the
Machinery Directive 2006/42/EC. Commissioning is prohibited until the conformity of the
end product with this directive has been established (follow i. a. EN 60204−1).
Lowvoltage machines with IP23 protection or less are only intended for outdoor use when
applying special protective features.
The integrated brakes must not be used as safety brakes. It cannot be ruled out that factors
which cannot be influenced, such as oil ingress due to a defective Aside shaft seal, cause
a brake torque reduction.
Transport, storage
Damages must be reported immediately upon receipt to the forwarder; if required,
commissioning must be excluded. Tighten screwedin ring bolts before transport. They are
designed for the weight of the lowvoltage machines, do not apply extra loads. If necessary,
use suitable and adequately dimensioned means of transport (e. g. rope guides).
Remove transport locking devices before commissioning. Reuse them for further
transport. When storing low−voltage machines, ensure a dry, dustfree and low−vibration
(v
eff
£
0.2 mm/s) environment (bearing damage while being stored).
Содержание E70AC Series
Страница 1: ...EDS700ACBA Usx Usx Hardware Manual i700 l E70AC Servo Inverter i700 Translation...
Страница 2: ...0Fig 0Tab 0...
Страница 75: ...Mechanical installation 5 l 75 EDS700ACBA EN 5 1...
Страница 147: ...Accessories overview Terminals 11 l 147 EDS700ACBA EN 5 1 E70AZEVK001 i700ZM001 A...
Страница 148: ...Accessories overview Terminals 11 l 148 EDS700ACBA EN 5 1 E70AZEVK002 i700ZM001 C...
Страница 149: ...Accessories overview Terminals 11 l 149 EDS700ACBA EN 5 1 E70AZEVK003 i700ZM001 B...
Страница 150: ...Accessories overview Terminals 11 l 150 EDS700ACBA EN 5 1 E70AZEVK004 i700ZM001 D...
Страница 151: ...Accessories overview Terminals 11 l 151 EDS700ACBA EN 5 1 E70AZEVK005 i700ZP005 a...
Страница 152: ...Accessories overview Terminals 11 l 152 EDS700ACBA EN 5 1 E70AZEVK006 i700ZP005 b...
Страница 157: ...Accessories overview EMC accessories Shield mounting 11 l 157 EDS700ACBA EN 5 1 ezamb_001 EZAMBKBM 10 mm 8 30 mm...
Страница 161: ......