Safety Information

Safety Information

1.1  Warnings, Cautions and Notes

1.1.1  General

Some parts of Lenze controllers (frequency inverters, servo inverters, DC controllers) can be live, moving 
and rotating. Some surfaces can be hot.

Non-authorized removal of the required cover, inappropriate use, and incorrect installation or operation 
creates the risk of severe injury to personnel or damage to equipment.

All  operations  concerning  transport,  installation,  and  commissioning  as  well  as  maintenance  must  be 
carried out by qualified, skilled personnel (IEC 364 and CENELEC HD 384 or DIN VDE 0100 and IEC report 
664 or DIN VDE0110 and national regulations for the prevention of accidents must be observed).

According to this basic safety information, qualified skilled personnel are persons who are familiar with 
the installation, assembly, commissioning, and operation of the product and who have the qualifications 
necessary for their occupation.

1.1.2  Application

Drive controllers are components designed for installation in electrical systems or machinery. They are 
not to be used as appliances. They are intended exclusively for professional and commercial purposes 
according to EN 61000-3-2. The documentation includes information on compliance with EN 61000-3-2.

When installing the drive controllers in machines, commissioning (i.e. the starting of operation as directed) 
is prohibited until it is proven that the machine complies with the regulations of the EC Directive 98/37/EC 
(Machinery Directive); EN 60204 must be observed.

Commissioning (i.e. starting drive as directed) is only allowed when there is compliance to the EMC Directive 
(89/336/EEC).

The  drive  controllers  meet  the  requirements  of  the  Low  Voltage  Directive  73/23/EEC.  The  harmonised 
standards of the series EN 50178/DIN VDE 0160 apply to the controllers.

The availability of controllers is restricted according to EN 61800-3.  These products can cause 
radio interference in residential areas. In the case of radio interference, special measures may be 
necessary for drive controllers.

1.1.3  Installation

Ensure proper handling and avoid excessive mechanical stress. Do not bend any components and do not 
change any insulation distances during transport or handling. Do not touch any electronic components 
and contacts. Controllers contain electrostatically sensitive components, which can easily be damaged by 
inappropriate handling. Do not damage or destroy any electrical components since this might endanger 
your health! When installing the drive ensure optimal airflow by observing all clearance distances in the 
drive's user manual. Do not expose the drive to excessive: vibration, temperature, humidity, sunlight, dust, 
pollutants, corrosive chemicals or other hazardous environments.

Содержание AC Tech MCH Series

Страница 1: ...MCH Series Drives BACnet Communications Guide...

Страница 2: ...nc 1791 Tullie Circle NE Atlanta GA 30329 http www bacnet org Modbus is a registered trademark of Schneider Electric founder of Modbus IDA http www modbus IDA org 2003 AC Technology Corporation No par...

Страница 3: ...ed Programming Parameters 4 3 2 Omitted Parameters and Selections 4 3 3 Modified Parameters and Selections 5 3 4 Serial Communication Setup 5 4 MCH BACnet Objects 8 4 1 BACnet Object Map 8 4 2 Analog...

Страница 4: ...n installing the drive controllers in machines commissioning i e the starting of operation as directed is prohibited until it is proven that the machine complies with the regulations of the EC Directi...

Страница 5: ...adapt the controller to your application as described in the documentation DANGER After the controller has been disconnected from the supply voltage do not touch the live components and power connect...

Страница 6: ...length of an MS TP segment is 1200 meters 4000 feet with AWG 18 cable Maximum number of nodes unit loads per segment is 32 as specified by the EIA 485 standard Because MS TP uses non return to zero N...

Страница 7: ...e of bits 0 15 of the drive s 22 bit device number It can be used by itself to represent a device number in the range of 0 to 65535 If the device number exceeds 65535 then DEVICE NUM EX must also be u...

Страница 8: ...ng of all MCH BACnet points Write commands will not be accepted without proper modification to these drive settings One exception to this is STOP commands which are always accepted over the LAN For se...

Страница 9: ...erial watchdog timeout occurrence The options for this parameter are FAULT default and PRESET 3 If FAULT is selected and the drive is running when a serial watchdog timeout occurs the drive will trip...

Страница 10: ...of serial control If Drive Parameter 30 Control is set to SERIAL AUTO and the drive was running when the timeout occurred the drive will also stop the motor by tripping into a SERIAL FAULT A fault res...

Страница 11: ...ommand PID SETPOINT 1 00 50 AI 7 PID Feedback PID FEEDBACK 1 00 0 AV 1 Keypad Speed Command KEY SPD CMD Hz 0 01 20 00 AV 2 Keypad Setpoint Command KEY STPT CMD 1 00 50 BI 1 Run Stop Status RUN_STOP 1...

Страница 12: ...back This object is for monitoring the current PID Feedback value at the input specified by Drive Parameter 74 PID Feedback The range of this object is defined by Drive Parameter 75 Feedback Min and D...

Страница 13: ...information Object BI 6 Relay 1 This object monitors the state of the drive s Relay 1 output This object can be used to indicate various drive conditions as specified by Drive Parameter 54 RELAY1 Ref...

Страница 14: ...his object indicates the type of fault on which the drive is currently tripped This object returns a value between 1 and 25 which corresponds to one of the following fault conditions Value Name Fault...

Страница 15: ...is for monitoring the source of the speed setpoint reference States 1 through 9 are speed references States 10 through 18 are setpoint references This object must be in state 1 9 or 10 for the LAN to...

Страница 16: ...peed Source Selection This object mimics the functionality of the SPEED SOURCE key on the drive keypad It is used to determine whether the drive will get its speed setpoint reference from Drive Parame...

Страница 17: ...AC Technology Corporation 630 Douglas Street Uxbridge MA 01569 USA Sales 800 217 9100 Service 508 278 9100 www lenze actech com RG MHBAC e2...

Отзывы: