T
Commissioning
The most important codes for commissioning
EDK82MV222 DE/EN/FR 9.0
L
NOM
Code
Possible settings
IMPORTANT
No.
Name
Lenze Selection
C0002*
uSEr
Parameter set
management
-11-
0
0
Ready
PAR1 ... PAR4:
z
Parameter sets of the
controller
z
PAR1 ... PAR4 also contain
parameters for
Standard-I/O,
Application-I/O,
AS interface or system
bus (CAN)
FPAR1:
z
Module-specific
parameter set of the
fieldbus function modules
INTERBUS, PROFIBUS-DP,
LECOM-B,
DeviceNet/CANopen
z
FPAR1 is saved in the
function module
Restorage of
default setting
1
Lenze setting
Ö
PAR1
Restorage of default setting
in the selected parameter set
2
Lenze setting
Ö
PAR2
3
Lenze setting
Ö
PAR3
4
Lenze setting
Ö
PAR4
31
Lenze setting
Ö
FPAR1
Restorage of default setting
in the fieldbus function
module
61
Lenze setting
Ö
PAR1 + FPAR1
Restorage of default setting
in the selected parameter set
of the controller and the
fieldbus function module
62
Lenze setting
Ö
PAR2 + FPAR1
63
Lenze setting
Ö
PAR3 + FPAR1
64
Lenze setting
Ö
PAR4 + FPAR1
C0002*
uSEr
(cont.)
Parameter set
transfer using
the keypad
Use the keypad to transfer
parameter sets to other
controllers.
During transfer the
parameters cannot be
accessed via other
channels!
Keypad
Ö
Controller
All available parameter sets
(PAR1 ... PAR4, and FPAR1)
are overwritten with the
corresponding keypad data
70
With function module
Application-I/O, INTERBUS,
PROFIBUS-DP, LECOM-B,
DeviceNet/CANopen
10
With all other function modules
efesotomasyon.com - Lenze
All manuals and user guides at all-guides.com