Parameter setting
6-8
BA2112EN
6.1.2
Unit control
(C0009 = 11)
In the following the bit assignment of control and status word is under C0009 = 11:
6.1.2.1
Control word
Control word for 82XX and 8200 vector
820X
821x,822x
8200vector
820X
821x,822x
Factory setting:
C0001= 3 if C0007 < 52
Factory setting:
C001= 3 if C0007 > 51
0
JOG1, JOG2, JOG3
00 = C0046 active
01 = JOG1 (C0037) active
10 = JOG2 (C0038) active
11 = JOG3 (C0039) active
JOG1, JOG2, JOG3
00 = C0046 active
01 = JOG1 (C0037) active
10 = JOG2 (C0038) active
11 = JOG3 (C0039) active
NSET1-JOG1/3
00 = C0046 active
01 = JOG1 (C0037) active
10 = JOG2 (C0038) active
11 = JOG3 (C0039) active
1
11 = JOG3 (C0039) active
11 = JOG3 (C0039) active
NSET1-JOG2/3
2
CW/CCW (CW rotation/CCW rotation)
0 = CW rotation
1 = CCW rotation
CW/CCW (CW rotation/CCW rotation)
0 = CW rotation
1 = CCW rotation
DCTRL1-CW/CCW
0 = not active
1 = active
3
QSP (quick stop)
0 = QSP not active
1 = QSP active
QSP (quick stop)
0 = QSP not active
1 = QSP active
AIF-CTRL-QSP
0 = not active
1 = active
4
Reserved
RFG stop (stop of the ramp function
generator)
0 = RFG stop not active
1 = RFG stop active
NSET1-RFG1-STOP
0 = not active
1 = active
5
Reserved
RFG zero (deceleration along the T i f
ramp C0013)
0 = RFG zero not active
1 = RFG zero active
NSET1-RFG1-0
0 = not active
1 = active
6
Reserved
UP function for motor potentiometer
0 = UP not active
1 = UP active
MPOT1-UP
0 = not active
1 = active
The default setting (see below) is
accepted with setting C0007 > 51
Use C0410 to set your own
7
Reserved
DOWN function for motor
potentiometer
0 = DOWN not active
1 = DOWN active
MPOT1-DOWN
0 = not active
1 = active
Use C0410 to set your own
configurations.
8
Reserved
Reserved
Reserved
9
Ctrl. inhibit (controller inhibit)
0 = controller not inhibited
1 = controller inhibited
Ctrl. inhibit (controller inhibit)
0 = controller not inhibited
1 = controller inhibited
AIF-CTRL-CINH
0 = not active
1 = active
10
Reserved
Reserved
No function
11
Reserved
TRIP reset
0 -> 1 = Edge from 0 to 1
AIF-CTRL-TRIP-RESET
0 -> 1 = Edge from 0 to 1
12
PAR1 (Parameter set changeover)
0 -> 1 = Parameter set
1 -> 0 = Parameter set
PAR1 (Parameter set changeover)
0 -> 1 = Parameter set
1 -> 0 = Parameter set
DCTRL1-PAR2/4
0 = not active
1 = active
13
Reserved
Reserved
DCTRL1-PAR3/4
0 = not active
1 = active
14
DC brake (DC injection brake)
0 = DC brake not active
1 = DC brake active
DC brake (DC injection brake)
0 = DC brake not active
1 = DC brake active
MCTRL1-DCB
0 = not active
1 = active
15
Reserved
Reserved
Reserved
Show/Hide Bookmarks
Содержание 2112
Страница 12: ...Technical data 3 4 BA2112EN Show Hide Bookmarks ...
Страница 16: ...Installation 4 4 BA2112EN Show Hide Bookmarks ...
Страница 22: ...Commissioning 5 6 BA2112EN Show Hide Bookmarks ...
Страница 52: ...Appendix 8 6 BA2112EN Show Hide Bookmarks ...
Страница 53: ...Appendix 8 7 BA2112EN Show Hide Bookmarks ...