background image

Page 2

G51MP Parts Identification

DURALOK

TM 

HEAT

EXCHANGER

ASSEMBLY

UPPER ACCESS

PANEL

BURNERS

BLOWER

MOTOR

CABINET

CONTROL BOX

GAS VALVE AND

MANIFOLD

COMBUSTION AIR

PROVING

(PRESSURE)

SWITCH

COMBUSTION AIR

INDUCER

BLOWER ACCESS

PANEL

FLUE

COLLAR

TOP CAP

SURELIGHT

t

 CONTROL BOARD

FIGURE 1

WARNING

Product contains fiberglass wool.
Disturbing  the  insulation  in  this  product  during

installation, maintenance, or repair will expose you

to fiberglass wool. Breathing this may cause lung

cancer. (Fiberglass wool is known to the State of CalĆ

ifornia to cause cancer.)
Fiberglass  wool  may  also  cause  respiratory,  skin,

and eye irritation.
To reduce exposure to this substance or for further

information,  consult  material  safety  data  sheets

available from address shown below, or contact your

supervisor.

Lennox Industries Inc.

P.O. Box 799900

Dallas, TX 75379-9900

NOTE - This manual must be left with the equipment
user.

WARNING

Do not set thermostat below 60°F (16°C) in heating

mode. Setting thermostat below 60°F (16°C) reduces

the number of heating cycles. Damage to the unit

may occur that is not covered by the warranty.

WARNING

If overheating occurs or if gas supply fails to shut off,

shut off the manual gas valve to the furnace before

shutting off electrical supply.

CAUTION

Before attempting to perform any service or mainteĆ

nance, turn the electrical power to unit OFF at the

disconnect switch.

Содержание 2P0803

Страница 1: ... qualified installer service agency or the gas supplier D Do not try to light any appliance D Do not touch any electrical switch do not use any phone in your building D Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions D If you cannot reach your gas supplier call the fire department FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactĆ ly...

Страница 2: ... respiratory skin and eye irritation To reduce exposure to this substance or for further information consult material safety data sheets available from address shown below or contact your supervisor Lennox Industries Inc P O Box 799900 Dallas TX 75379 9900 NOTE This manual must be left with the equipment user WARNING Do not set thermostat below 60 F 16 C in heating mode Setting thermostat below 60...

Страница 3: ...stion and the formation of carbon monoxide gas This toxic gas might then be distributed throughout the house by the furnace duct system WARNING The blower door must be securely in place when the blower and burners are operating Gas fumes which could contain carbon monoxide can be drawn into the living space resulting in personal injury or death Your furnace is a gas appliance It is critical that t...

Страница 4: ... gas supplier s instrucĆ tions If you do not smell gas go to next step 8 White Rodgers 36G Gas Valve Switch gas valve lever to ON See figure 3 for the White Rodgers 36G valve Honeywell VR8205 Gas Valve Turn knob on gas valve counterclockwise to ON Do not force FIGURE 3 White Rodgers 36G Series Gas Valve GAS VALVE SHOWN IN OFF POSITION MANIFOLD PRESSURE ADJUSTMENT SCREW OUTLET PRESSURE POST INLET P...

Страница 5: ... deterioration or deposits of debris Remove any obĆ structions Inspect the furnace for obvious signs of deterioration Inspect the furnace venting system to make sure it is in place physically sound and without holes corrosion or blockage Vent pipe must be clear and free of obstructions and must slope upward away from the furnace Inspect the furnace return air duct connection to ensure duct is seal...

Страница 6: ... flu like sympĆ toms that are exaggerated at home but seem to subĆ side while you are away from the house exposure to carbon monoxide could be the cause Your vigilance may pay off in early detection of a problem before either personal injury or property damage occurs Do not hesitate to contact a qualified service technician as an investment in your well being Planned Service You should expect a se...

Страница 7: ...op Cap Control Panel Parts Transformer SureLight integrated control board Door interlock switch Circuit Breaker Blower Parts Blower wheel Motor Motor mounting frame Motor capacitor Blower housing cutoff plate Heating Parts Flame Sensor Heat exchanger assembly Gas manifold Combustion air inducer Gas valve Main burner cluster Main burner orifices Pressure switches Ignitor Primary limit control Secon...