• PCIe switch card: slot 1, 11
For PCIe slot numbering, see “System-board connectors” on page 24.
Step 3. Push the adapter in until it clicks into place.
Figure 103. Adapter installation to the system board
Step 4. Connect internal cables to the adapter. Follow instructions of internal cable routing for adapters
(see “Internal cable routing” on page 35).
Step 5. Close the retention latch.
Install an adapter in a PCIe riser card assembly
To install an adapter to a PCIe riser card assembly removed from the server, complete the following steps:
Note:
When both LOM adapter and ML2 adapter are installed to the server, the system can support up to
two additional network adapters.
Step 1. Open the bracket on the PCIe riser card assembly.
Step 2. Align the adapter with the connector on the PCIe riser card assembly.
Step 3. Push the adapter into the PCIe riser card assembly until it clicks into place.
.