3. Remove or disconnect the following devices, one at a time, until you find the failure. Power on and
configure the server each time you remove or disconnect a device.
• Any external devices,
• Surge-suppressor device (on the server).
• Printer, mouse, and non-Lenovo devices,
• Each adapter.
• Hard disk drives.
• Memory modules until you reach the minimum configuration that is supported for the server.
Note:
For minimal configuration for debugging, see “Specifications” on page 3.
4. Power on the server.
If the problem is solved when you remove an adapter from the server, but the problem recurs when you
install the same adapter again, suspect the adapter. If the problem recurs when you replace the adapter with
a different one, try a different PCIe slot.
If the problem appears to be a networking problem and the server passes all system tests, suspect a network
cabling problem that is external to the server.
Resolving suspected power problems
Power problems can be difficult to solve. For example, a short circuit can exist anywhere on any of the power
distribution buses. Usually, a short circuit will cause the power subsystem to shut down because of an
overcurrent condition.
Complete the following steps to diagnose and resolve a suspected power problem.
Step 1. Check the event log and resolve any errors related to the power.
Note:
Start with the event log of the application that is managing the server. For more information
about event logs, see “Event logs” on page 205.
Step 2. Check for short circuits, for example, if a loose screw is causing a short circuit on a circuit board.
Step 3. Remove the adapters and disconnect the cables and power cords to all internal and external
devices until the server is at the minimum configuration that is required for the server to start. See
“Specifications” on page 3 to determine the minimum configuration for your server.
Step 4. Reconnect all ac power cords and turn on the server. If the server starts successfully, reseat the
adapters and devices one at a time until the problem is isolated.
If the server does not start from the minimum configuration, replace the components in the minimum
configuration one at a time until the problem is isolated.
Resolving suspected Ethernet controller problems
The method that you use to test the Ethernet controller depends on which operating system you are using.
See the operating-system documentation for information about Ethernet controllers, and see the Ethernet
controller device-driver readme file.
Complete the following steps to attempt to resolve suspected problems with the Ethernet controller.
Step 1. Make sure that the correct device drivers, which come with the server are installed and that they
are at the latest level.
Step 2. Make sure that the Ethernet cable is installed correctly.
• The cable must be securely attached at all connections. If the cable is attached but the problem
remains, try a different cable.
207
Содержание ThinkSystem SR635
Страница 1: ...ThinkSystem SR635 Maintenance Manual Machine Types 7Y98 and 7Y99 ...
Страница 5: ...Index 231 Copyright Lenovo 2019 2021 iii ...
Страница 6: ...iv ThinkSystem SR635 Maintenance Manual ...
Страница 10: ...viii ThinkSystem SR635 Maintenance Manual ...
Страница 12: ...Figure 2 QR code 2 ThinkSystem SR635 Maintenance Manual ...
Страница 22: ...12 ThinkSystem SR635 Maintenance Manual ...
Страница 88: ...78 ThinkSystem SR635 Maintenance Manual ...
Страница 133: ...Figure 102 Riser 1 assembly LP FHFL removal Chapter 3 Hardware replacement procedures 123 ...
Страница 136: ...Figure 105 Riser 1 assembly LP FHFL installation 126 ThinkSystem SR635 Maintenance Manual ...
Страница 214: ...204 ThinkSystem SR635 Maintenance Manual ...
Страница 232: ...222 ThinkSystem SR635 Maintenance Manual ...
Страница 240: ...230 ThinkSystem SR635 Maintenance Manual ...
Страница 245: ......
Страница 246: ......