Serial-device problems
Use this information to solve problems with serial ports or devices.
• “Number of displayed serial ports is less than the number of installed serial ports” on page 179
• “Serial device does not work” on page 179
Number of displayed serial ports is less than the number of installed serial ports
Complete the following steps until the problem is solved.
1. Make sure that:
• Each port is assigned a unique address in the Setup utility and none of the serial ports is disabled.
• The serial-port adapter (if one is present) is seated correctly
2. Reseat the serial port adapter.
3. Replace the serial port adapter.
Serial device does not work
1. Make sure that:
• The device is compatible with the server.
• The serial port is enabled and is assigned a unique address.
• The device is connected to the correct connector.
2. Reseat the following components:
a. Failing serial device.
b. Serial cable.
3. Replace the following components:
a. Failing serial device.
b. Serial cable.
4. (Trained technician only) Replace the system board.
Intermittent problems
Use this information to solve intermittent problems.
• “Intermittent external device problems” on page 179
• “Intermittent KVM problems” on page 180
• “Intermittent unexpected reboots” on page 180
Intermittent external device problems
Complete the following steps until the problem is solved.
1. Make sure that the correct device drivers are installed. See the manufacturer's website for
documentation.
2. For a USB device:
a. Make sure that the device is configured correctly.
Restart the server and press F1 to display the Lenovo XClarity Provisioning Manager system setup
interface. Then, click
System Settings
➙
Devices and I/O Ports
➙
USB Configuration
.
b. Connect the device to another port. If using a USB hub, remove the hub and connect the device
directly to the compute node. Make sure that the device is configured correctly for the port.
179
Содержание ThinkSystem SR550
Страница 1: ...ThinkSystem SR550 Maintenance Manual Machine Types 7X03 and 7X04 ...
Страница 8: ...vi ThinkSystem SR550 Maintenance Manual ...
Страница 49: ...Chapter 2 Server components 41 ...
Страница 60: ...52 ThinkSystem SR550 Maintenance Manual ...
Страница 113: ...Figure 80 Riser 1 assembly removal Chapter 3 Hardware replacement procedures 105 ...
Страница 174: ...166 ThinkSystem SR550 Maintenance Manual ...
Страница 192: ...184 ThinkSystem SR550 Maintenance Manual ...
Страница 196: ...188 ThinkSystem SR550 Maintenance Manual ...
Страница 200: ...192 ThinkSystem SR550 Maintenance Manual ...
Страница 205: ......
Страница 206: ......