Table 1. Server specifications (continued)
Specification
Description
Power supplies
One or two hot-swap power supplies for redundancy support
• 550-watt ac 80 PLUS Platinum
• 750-watt ac 80 PLUS Platinum
• 750-watt ac 80 PLUS Titanium
Acoustical noise emissions
• Sound power levels, idle
– 4.9 bels, minimum
– 5.3 bels, typical
– 6.1 bels, maximum
• Sound power levels, operating
– 4.9 bels, minimum
– 5.5 bels, typical
– 6.2 bels, maximum
Notes:
• These sound power levels are measured in controlled acoustical environments
according to procedures specified by ISO 7779 and are reported in accordance
with ISO 9296.
• The declared acoustic noise levels are based on specified configurations and they
may change depending on configurations/conditions.
• The declared acoustic noise levels may increase greatly, if high-power
components are installed, for example, some high-power NICs, CPUs, and GPUs.
Minimal configuration for
debugging
• One processor in processor socket 1
• One DIMM in slot 3
• One power supply
• Three system fans (fan 1 to fan 3)
6
ThinkSystem SR550 Maintenance Manual
Содержание ThinkSystem SR550
Страница 1: ...ThinkSystem SR550 Maintenance Manual Machine Types 7X03 and 7X04 ...
Страница 8: ...vi ThinkSystem SR550 Maintenance Manual ...
Страница 49: ...Chapter 2 Server components 41 ...
Страница 60: ...52 ThinkSystem SR550 Maintenance Manual ...
Страница 113: ...Figure 80 Riser 1 assembly removal Chapter 3 Hardware replacement procedures 105 ...
Страница 174: ...166 ThinkSystem SR550 Maintenance Manual ...
Страница 192: ...184 ThinkSystem SR550 Maintenance Manual ...
Страница 196: ...188 ThinkSystem SR550 Maintenance Manual ...
Страница 200: ...192 ThinkSystem SR550 Maintenance Manual ...
Страница 205: ......
Страница 206: ......