Intermittent KVM problems
Complete the following steps until the problem is solved.
Video problems:
1. Make sure that all cables and the console breakout cable are properly connected and secure.
2. Make sure that the monitor is working properly by testing it on another compute node.
3. Test the console breakout cable on a working compute node to ensure that it is operating properly.
Replace the console breakout cable if it is defective.
Keyboard problems:
Make sure that all cables and the console breakout cable are properly connected and secure.
Mouse problems:
Make sure that all cables and the console breakout cable are properly connected and secure.
Intermittent unexpected reboots
Note:
Some correctable errors require that the server reboot so that it can disable a device, such as a
memory DIMM or a microprocessor to allow the machine to boot up properly.
1. If the reset occurs during POST and the POST watchdog timer is enabled, make sure that sufficient time
is allowed in the watchdog timeout value (POST Watchdog Timer).
To check the POST watchdog time, restart the server and press F1 to display the Lenovo XClarity
Provisioning Manager system setup interface. Then, click
BMC Settings
➙
POST Watchdog Timer
.
2. If the reset occurs after the operating system starts, disable any automatic server restart (ASR) utilities,
such as the Automatic Server Restart IPMI Application for Windows, or any ASR devices that are
installed.
3. See the management controller event log to check for an event code that indicates a reboot. See “Event
logs” on page 167 for information about viewing the event log.
Power problems
Use this information to resolve issues related to power.
System error LED is on and event log "Power supply has lost input" is displayed
To resolve the problem, ensure that:
1. The power supply is properly connected to a power cord.
2. The power cord is connected to a properly grounded electrical outlet for the server.
Network problems
Use this information to resolve issues related to networking.
• “Cannot wake server using Wake on LAN” on page 180
• “Could not log in using LDAP account with SSL enabled” on page 181
Cannot wake server using Wake on LAN
Complete the following steps until the problem is resolved:
180
ThinkSystem SR550 Maintenance Manual
Содержание ThinkSystem SR550
Страница 1: ...ThinkSystem SR550 Maintenance Manual Machine Types 7X03 and 7X04 ...
Страница 8: ...vi ThinkSystem SR550 Maintenance Manual ...
Страница 49: ...Chapter 2 Server components 41 ...
Страница 60: ...52 ThinkSystem SR550 Maintenance Manual ...
Страница 113: ...Figure 80 Riser 1 assembly removal Chapter 3 Hardware replacement procedures 105 ...
Страница 174: ...166 ThinkSystem SR550 Maintenance Manual ...
Страница 192: ...184 ThinkSystem SR550 Maintenance Manual ...
Страница 196: ...188 ThinkSystem SR550 Maintenance Manual ...
Страница 200: ...192 ThinkSystem SR550 Maintenance Manual ...
Страница 205: ......
Страница 206: ......