background image

Notices

Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your
local Lenovo representative for information on the products and services currently available in your area. Any
reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product,
program, or service may be used. Any functionally equivalent product, program, or service that does not infringe
any Lenovo intellectual property right may be used instead. However, it is the user's responsibility to evaluate and
verify the operation of any other product, program, or service. Lenovo may have patents or pending patent
applications covering subject matter described in this document. The furnishing of this document does not give you
any license to these patents. You can send license inquiries, in writing, to:

Lenovo (United States), Inc.
1009 Think Place - Building One
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing

LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT,
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of
express or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the
information herein; these changes will be incorporated in new editions of the publication. Lenovo may make
improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time
without notice.

The products described in this document are not intended for use in implantation or other life support applications
where malfunction may result in injury or death to persons. The information contained in this document does not
affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express
or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information
contained in this document was obtained in specific environments and is presented as an illustration. The result
obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply
in any way it believes appropriate without incurring any obligation to you.

Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any
manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials
for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was
determined in a controlled environment. Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level systems and there is no guarantee
that these measurements will be the same on generally available systems. Furthermore, some measurements may
have been estimated through extrapolation. Actual results may vary. Users of this document should verify the
applicable data for their specific environment.

© Copyright Lenovo 2017. All rights reserved.

 

This document, LP0607, was created or updated on June 27, 2017.

Send us your comments in one of the following ways:

Use the online Contact us review form found at:

https://lenovopress.com/LP0607

Send your comments in an e-mail to:

[email protected]

This document is available online at 

https://lenovopress.com/LP0607

.

Lenovo ThinkSystem NE1072T RackSwitch

24

Содержание ThinkSystem NE1072T

Страница 1: ... or active optical breakout cables The switch is ideal for latency sensitive applications such as high performance computing clusters and financial applications The Lenovo ThinkSystem NE1072T RackSwitch is shown in the following figure Figure 1 Lenovo ThinkSystem NE1072T RackSwitch Did you know With exceptional port density and flexibility with break out cables the NE1072T RackSwitch can support u...

Страница 2: ...erformance and lower latency The NE1072T RackSwitch offers the following features and benefits High performance The 10 Gb 40 Gb NE1072T RackSwitch provides a combination of low latency non blocking line rate switching and ease of management with 1 44 Tbps throughput Lower power and better cooling The front to rear or rear to front cooling design of the NE1072T RackSwitch reduces data center air co...

Страница 3: ...Scripting Network administrators can create and execute local Python scripts on switches to make small programs that allow a switch to automatically provision itself perform fault monitoring upgrade the image files or auto generate configuration files Administrators can also implement version control systems automatically generate alerts create custom logging tools and automate the management of n...

Страница 4: ...ernet port for out of band management One Mini USB RS 232 console port that provides another means to configure the switch One USB port for mass storage devices LEDs that display the status of the switch and the network Reset button Switch information pull out tab The following figure shows the rear non port side panel of the NE1072T RackSwitch Figure 3 Rear panel of the NE1072T RackSwitch The rea...

Страница 5: ...virtual local area networks VLANs VLAN tagging spanning tree protocol STP link aggregation trunk groups LAGs virtual LAGs vLAGs quality of service QoS IPv4 IPv6 management IPv4 IPv6 routing IPv4 IPv6 virtual router redundancy protocol VRRP IPv4 IPv6 policy based routing PBR Converged Enhanced Ethernet Network Policy Agent Python scripting REST API programming Telemetry agent Performance Non blocki...

Страница 6: ... Weight 11 5 kg 25 4 lb Component Specification Models The following table lists the NE1072T RackSwitch models Table 2 NE1072T RackSwitch models Description Part number Machine Type Model Feature code Lenovo ThinkSystem NE1072T RackSwitch Rear to Front 7159C1X 7159 HD5 AU36 Lenovo ThinkSystem NE1072T RackSwitch Front to Rear 7159C2X 7159 HD6 AU35 The part numbers for the NE1072T RackSwitch models ...

Страница 7: ...or distances up to 400 meters For 40 GbE to 40 GbE connectivity customers can use the affordable QSFP to QSFP DAC cables for distances up to 7 meters or QSFP to QSFP active optical cables for distances up to 20 meters These DAC cables and AOCs have QSFP connectors on each end and they do not need separate transceivers With multimode fiber optic LC cables customers can use the 40GBASE QSFP bi direc...

Страница 8: ... Lenovo 3m QSFP to QSFP Active Optical Cable 00YL652 ATZ3 6 Lenovo 5m QSFP to QSFP Active Optical Cable 00YL655 ATZ4 6 Lenovo 7m QSFP to QSFP Active Optical Cable 00YL658 ATZ5 6 Lenovo 15m QSFP to QSFP Active Optical Cable 00YL661 ATZ6 6 Lenovo 20m QSFP to QSFP Active Optical Cable 00YL664 ATZ7 6 QSFP active optical breakout cables 40 GbE to 4x10 GbE Lenovo 1m QSFP to 4xSFP Active Optical Cable 00...

Страница 9: ...Gb eSR4 QSFP 00FE325 40GBASE SR4 10 m or 30 m MPO fiber optic cables or MPO 4xLC breakout cables up to 5 m supplied by Lenovo see Table 4 support for up to 300 m with OM3 or up to 400 m with OM4 multimode fiber optic cable MPO 40Gb LR4 QSFP 00D6222 40GBASE LR4 1310 nm single mode fiber optic cable up to 10 km LC Active optical cable 40GBASE SR4 QSFP to QSFP active optical cables up to 20 m QSFP to...

Страница 10: ...LAN support Up to 4095 VLANs supported per switch with VLAN numbers 1 4095 VLAN 4095 is used by the management network Port based VLANs 802 1Q VLAN tagging support Ingress VLAN tagging support to tunnel packets through a public domain without altering the original 802 1Q tagging information Security VLAN based MAC based and IP based access control lists ACLs Multiple user IDs and passwords User ac...

Страница 11: ...rconverged Nutanix environment requires the Acropolis hypervisor and software version 5 0 2 or higher Converged Enhanced Ethernet Priority Based Flow Control PFC IEEE 802 1Qbb extends 802 3x standard flow control to allow the switch to pause traffic that is based on the 802 1p priority value in each packet s VLAN tag Enhanced Transmission Selection ETS IEEE 802 1Qaz provides a method for allocatin...

Страница 12: ...ment Ganglia plug in for telemetry data analytics Ethernet standards The NE1072T RackSwitch supports the following Ethernet standards IEEE 802 1AB Data Center Bridging Capability Exchange Protocol DCBX IEEE 802 1D Spanning Tree Protocol STP IEEE 802 1p Class of Service CoS prioritization IEEE 802 1s Multiple STP MSTP IEEE 802 1Q Tagged VLAN frame tagging on all ports when VLANs are enabled IEEE 80...

Страница 13: ...4 6211 Brazil 10A 125V C13 to NBR 6147 2 8m line cord 39Y7929 6223 China 10A 250V C13 to GB 2099 1 2 8m line cord 39Y7928 6210 Denmark 10A 250V C13 to DK2 5a 2 8m line cord 39Y7918 6213 European 10A 230V C13 to CEE7 VII 2 8m line cord 39Y7917 6212 India 10A 250V C13 to IS 6538 2 8m line cord 39Y7927 6269 Israel 10A 250V C13 to SI 32 2 8m line cord 39Y7920 6218 Italy 10A 250V C13 to CEI 23 16 2 8m ...

Страница 14: ...ront airflow 7159 HD5 Lenovo RackSwitch Adjustable 19 4 Post Rail Kit 00D6185 A3KP Air Inlet Duct for 487 mm RackSwitch 00FM507 ASTN Front to rear airflow 7159 HD6 Lenovo RackSwitch Adjustable 19 4 Post Rail Kit 00D6185 A3KP Lenovo RackSwitch Recessed 19 4 Post Rail Kit 00CG089 A51M Physical specifications The NE1072T RackSwitch features the following physical specifications Height 44 mm 1 7 in Wi...

Страница 15: ...ess day target response time Remote Technical Support 1 or 3 years Remote Technical Support RTS provides comprehensive technical call center support RTS can reduce problem resolution time which decreases the cost to address technical problems and increases uptime Hardware Installation Services Networking Lenovo experts can seamlessly manage the physical installation of your networking hardware Wor...

Страница 16: ...irflow that are offered by Lenovo that can be used with the N1072T RackSwitch in network connectivity solutions for System x ThinkServer and Flex System hosts Table 8 Network switches rear to front airflow Description Part number 1 Gb Ethernet switches Lenovo RackSwitch G7028 Rear to Front 7159BAX Lenovo RackSwitch G7052 Rear to Front 7159CAX Lenovo RackSwitch G8052 Rear to Front 7159G52 10 Gb Eth...

Страница 17: ...ed I O Modules http lenovopress com networking embedded 10gb rt product guide Storage connectivity The following table lists the external storage systems that are currently offered by Lenovo that can be used with the NE1072T RackSwitch for external NAS or iSCSI SAN storage connectivity Table 10 External storage systems Description Part number Lenovo ThinkSystem DS Series Storage Lenovo ThinkSystem...

Страница 18: ...age DX8200D Storage Virtualization Mid 16TB 3yr SW S S 5135B2x Lenovo Storage DX8200D Storage Virtualization Mid 16TB 5yr SW S S 51352Vx Lenovo Storage DX8200D Storage Virtualization Mid 16TB 4yr SW S S 5135L2x Lenovo Storage DX8200D Storage Virtualization High 64TB 3yr SW S S 5135C2x Lenovo Storage DX8200D Storage Virtualization High 64TB 4yr SW S S 5135M2x Lenovo Storage DX8200D Storage Virtuali...

Страница 19: ...ntroller Unit w 3 Yr S S Model 524 6195SC5 IBM Storwize V7000 2 5 inch Storage Controller Unit w 3 Yr S S LA Model 524 6195SCL IBM Storwize V7000 2 5 inch Storage Controller Unit w 5 Yr S S Model 524 61951F1 IBM Storwize V7000 2 5 inch Storage Controller Unit w 5 Yr S S LA Model 524 61951FL IBM Storwize V7000 SFF Control Enclosure 3YR SWMA Model HC1 Gen2 6195C32 IBM Storwize V7000 SFF Control Encl...

Страница 20: ...n IT solutions Table 12 Power distribution units Description Part number 0U Basic PDUs 0U 36 C13 6 C19 24A 200 240V 1 Phase PDU with NEMA L6 30P line cord 00YJ776 0U 36 C13 6 C19 32A 200 240V 1 Phase PDU with IEC60309 332P6 line cord 00YJ777 0U 21 C13 12 C19 32A 200 240V 346 415V 3 Phase PDU with IEC60309 532P6 line cord 00YJ778 0U 21 C13 12 C19 48A 200 240V 3 Phase PDU with IEC60309 460P9 line co...

Страница 21: ...t end PDU with IEC 309 2P Gnd line cord 39Y8940 DPI 63amp 250V Front end PDU with IEC 309 2P Gnd line cord 39Y8935 Universal PDUs 7x IEC 320 C13 outlets DPI Universal 7 C13 PDU with 2 m IEC 320 C19 to C20 rack power cord 00YE443 NEMA PDUs 6x NEMA 5 15R outlets DPI 100 127V PDU with fixed NEMA L5 15P line cord 39Y8905 Line cords for PDUs that ship without a line cord DPI 30a Line Cord NEMA L6 30P 4...

Страница 22: ...o maximize your purchase power by obtaining the technology you need today protect against technology obsolescence and preserve your capital for other uses We work with businesses non profit organizations governments and educational institutions to finance their entire technology solution We focus on making it easy to do business with us Our highly experienced team of finance professionals operates...

Страница 23: ...kSwitch Installation Guide Lenovo ThinkSystem NE1072T RackSwitch Application Guide Lenovo ThinkSystem NE1072T RackSwitch REST API Guide Lenovo ThinkSystem NE1072T RackSwitch Python Programming Guide The software for the NE1072T RackSwitch can be downloaded from Lenovo Data Center Support http datacentersupport lenovo com Related product families Product families related to this document are the fo...

Страница 24: ...t are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties...

Страница 25: ...ng terms are trademarks of Lenovo in the United States other countries or both Lenovo Lenovo XClarity ThinkServer NeXtScale System System x Flex System Intelligent Cluster NeXtScale RackSwitch ThinkSystem The following terms are trademarks of other companies Linux is a trademark of Linus Torvalds in the United States other countries or both Other company product or service names may be trademarks ...

Отзывы: