4. Connect cables to the drive.
2
1
4
5
3
Figure 34. Connecting cables to the drive
Cable
From the system board
To the drive
1-to-3 power cable
1
or
2
4-pin power connector
5
Power connector on the drive
Signal cable
3
SATA connector 1
4
Signal connector on the drive
Note:
The 1-to-3 power cable provides three SATA power connectors
1
,
2
, and
3
. You can connect
any one of the SATA connectors to the drive.
2
1
3
Storage drive in drive bay 3
Drive bay 3 of your server supports only a 2.5-inch hard disk drive or solid-state drive. For information about
drive bays and installation rules, see “Internal drives” on page 44.
•
“Removing a storage drive from drive bay 3” on page 58
•
“Installing a storage drive into drive bay 3” on page 60
Removing a storage drive from drive bay 3
To remove a storage drive from drive bay 3, do the following:
1. Prepare your server. See “Preparing your server and removing the server cover” on page 41.
2. Remove the front bezel. See “Front bezel” on page 42.
3. Disconnect the signal cable and power cable from the drive.
58
ThinkServer TS150 User Guide and Hardware Maintenance Manual
Содержание ThinkServer TS150
Страница 14: ...xii ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 52: ...38 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 116: ...102 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 124: ...110 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 135: ...Taiwan BSMI RoHS declaration Appendix C Restriction of Hazardous Substances RoHS Directive 121 ...
Страница 136: ...122 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 146: ...132 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 147: ......
Страница 148: ......