Installing a storage drive into drive bay 3
Note:
Drive bay 3 supports only a 2.5-inch hard disk drive or solid-state drive.
To install the storage drive, do the following:
1. Prepare your server. See “Preparing your server and removing the server cover” on page 41.
2. Remove the front bezel. See “Front bezel” on page 42.
3. If there is a metal shield covers the drive bay, remove the metal shield. Save the metal shield in case
that you later remove the drive and need the metal shield to cover the drive bay.
4. Install the drive into a 2.5-inch convertor kit. Align the four screw holes in the drive with the corresponding
screw holes in the convertor kit. Then, install screws to secure the drive to the convertor kit.
Figure 37. Installing the drive into a 2.5-inch convertor kit
5. Slide the 2.5-inch convertor kit into the drive bay until it snaps into position.
Figure 38. Installing the convertor kit into the drive bay
60
ThinkServer TS150 User Guide and Hardware Maintenance Manual
Содержание ThinkServer TS150
Страница 14: ...xii ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 52: ...38 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 116: ...102 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 124: ...110 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 135: ...Taiwan BSMI RoHS declaration Appendix C Restriction of Hazardous Substances RoHS Directive 121 ...
Страница 136: ...122 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 146: ...132 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 147: ......
Страница 148: ......