– Ports 47 and 48 of the RackSwitch G8272 TOR switches are connected to the customer border
switches.
– Port 51 of the RackSwitch G8052 BMC switch is connected to Port 46 of RackSwitch G8272 TOR
switch 1.
– Port 52 of the RackSwitch G8052 BMC switch is connected to Port 46 of RackSwitch G8272 TOR
switch 2.
• Deployment (10 GbE)
Port 49 of the RackSwitch G8052 BMC switch is connected to Mellanox Port 1 of System x3550 M5 HLH.
SXM4200/SXM6200 network cabling tables
The following tables list the point-to-point connections for each ThinkAgile SXM switch.
Note:
The settings apply regardless of the number of servers (4–12, depending on model) and whether the
product is in a 25U or 42U rack.
Table 2. SXM4200/SXM6200 network cabling for RackSwitch G8272 TOR Switch 2
Source
Port
Destination
Connection type
Device
Port
Optic
54
Reserved
n/a
n/a
n/a
53
Reserved
n/a
n/a
n/a
52
Reserved
n/a
n/a
n/a
51
Reserved
n/a
n/a
n/a
50
RackSwitch G8272 Switch 1 (TOR)
50
n/a
QSFP/QSFP, TwinAx, 1m
49
RackSwitch G8272 Switch 1 (TOR)
49
n/a
QSFP/QSFP, TwinAx, 1m
48
Border-2
Customer
10G-SR
LC/LC Fibre (Customer)
47
Border-1
Customer
10G-SR
LC/LC Fibre (Customer)
46
RackSwitch G8052 Switch (BMC)
52
n/a
SFP+/SFP+, TwinAx, 1m
45
RackSwitch G8272 Switch 1 (TOR)
45
n/a
SFP+/SFP+, TwinAx, 1m
44
RackSwitch G8272 Switch 1 (TOR)
44
n/a
SFP+/SFP+, TwinAx, 1m
43
n/a
n/a
n/a
n/a
42
n/a
n/a
n/a
n/a
41
n/a
n/a
n/a
n/a
40
n/a
n/a
n/a
n/a
39
n/a
n/a
n/a
n/a
38
n/a
n/a
n/a
n/a
37
n/a
n/a
n/a
n/a
36
n/a
n/a
n/a
n/a
35
n/a
n/a
n/a
n/a
34
n/a
n/a
n/a
n/a
33
n/a
n/a
n/a
n/a
32
n/a
n/a
n/a
n/a
40
Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator’s Guide
Содержание ThinkAgile SXM4200
Страница 4: ...ii Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...
Страница 6: ...iv Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...
Страница 8: ...vi Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...
Страница 14: ...6 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...
Страница 18: ...10 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...
Страница 20: ...12 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...
Страница 22: ...14 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...
Страница 26: ...18 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...
Страница 34: ...26 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...
Страница 38: ...30 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...
Страница 41: ...Figure 3 Front view of SXM4200 in 42U rack Appendix A SXM4200 SXM6200 models 33 ...
Страница 43: ...Figure 5 Front view of SXM6200 Appendix A SXM4200 SXM6200 models 35 ...
Страница 54: ...46 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...
Страница 68: ...60 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...
Страница 73: ......
Страница 74: ......