Lenovo ThinkAgile
SX for Microsoft Azure Stack
Administrator’s Guide

Models:

SXM4200, SXM6200, SXM4400, SXM6400

Содержание ThinkAgile SXM4200

Страница 1: ...Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide Models SXM4200 SXM6200 SXM4400 SXM6400 ...

Страница 2: ...t Lenovo 2017 LIMITED AND RESTRICTED RIGHTS NOTICE If data or software is delivered pursuant to a General Services Administration GSA contract use reproduction or disclosure is subject to restrictions set forth in Contract No GS 35F 05925 ...

Страница 3: ...ubleshooting ThinkAgile SXM issues 19 Troubleshooting considerations 19 Finding information and help 20 Isolating and resolving issues 20 Troubleshooting scenarios and tips 21 Isolating problems from XClarity 21 Isolating network problems 22 Isolating problems from switches 24 Chapter 9 Working with service and support 27 Opening a support case 27 Collecting data 28 Sending data to ThinkAgile Adva...

Страница 4: ...ii Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 5: ...of RackSwitch G8272 TOR switch 38 10 View of RackSwitch G8052 BMC switch 38 11 SXM4200 SXM6200 network and management cabling diagram 39 12 Front view of SXM4400 in 25U rack 47 13 Front view of SXM4400 in 42U rack 48 14 Front view of SXM6400 49 15 Views of ThinkSystem SR650 server nodes 50 16 Views of ThinkSystem SR630 HLH 50 17 View of ThinkSystem NE2572 TOR switch 51 18 View of RackSwitch G8052 ...

Страница 6: ...iv Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 7: ...witch 1 42 4 SXM4200 SXM6200 network cabling for RackSwitch G8052 BMC Switch 43 5 SXM4400 SXM6400 network cabling for ThinkSystem NE2572 TOR Switch 2 53 6 SXM4400 SXM6400 network cabling for ThinkSystem NE2572 TOR Switch 1 55 7 SXM4400 SXM6400 network cabling for RackSwitch G8052 BMC Switch 56 8 Power cabling for 25U rack 61 9 Power cabling for 42U rack 63 Copyright Lenovo 2017 v ...

Страница 8: ...vi Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 9: ... Azure Stack SXM4200 includes from four to twelve server nodes a Hardware Lifecycle Host server two top of rack switches and one BMC switch This can be ordered in a 42U rack only Models and Machine Types This documentation refers to the following products Table 1 ThinkAgile SXM Machine Type and Models Product Machine Type Model SXM4200 25U 9565 RCC SXM4200 42U 9565 RCD SXM6200 42U only 9565 RCE SX...

Страница 10: ...her Lenovo Data Center products See the following Web site https datacentersupport lenovo com Related Lenovo hardware documentation The following documentation describes ThinkAgile SXM components Some publications are also available in PDF format The following component documentation is relevant to the SXM4400 and SXM6400 models Product Documentation Web site ThinkSystem SR650 server Installation ...

Страница 11: ... x3650 m5 machine type 8871 System x3550 M5 server Installation and Service Guide Documentation http systemx lenovofiles com help topic com lenovo sysx 8869 doc c_product_page html Product guide https lenovopress com lp0067 lenovo system x3550 m5 machine type 8869 RackSwitch G8272 Installation Guide Application Guide ISCLI Industry Standard CLI Command Reference Documentation http systemx lenovofi...

Страница 12: ...for relevant Azure and Azure Stack information documentation and other resources Product description Web site Microsoft Azure https azure microsoft com Azure Stack product page https azure microsoft com overview azure stack Azure Stack usage and billing https docs microsoft com azure azure stack azure stack billing and chargeback Microsoft Azure documentation and tools https docs microsoft com en ...

Страница 13: ... for the various components Any specific firmware that is above or below the level indicated in the Best Recipe is not supported and might impact Lenovo s ability to support any issues with the relevant component See Chapter 6 Firmware maintenance and Best Recipe on page 13 for more details ThinkAgile SXM entitlement ThinkAgile SXM products are entitled at the rack level If you need support for th...

Страница 14: ...6 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 15: ...inkAgile SXM product setup and configuration by Lenovo Professional Services you should be able to manage the system routinely with the following software Lenovo XClarity Administrator management Use Lenovo XClarity Administrator to monitor and manage the hardware Typical uses include the following Firmware updates per the ThinkAgile SXM Best Recipe UEFI settings per the ThinkAgile SXM Best Recipe...

Страница 16: ...o work Consume VMs Plans and Offers that have been created by an administrator See ThinkAgile SXM documentation and related content on page 1 for relevant links 8 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 17: ...t documentation See ThinkAgile SXM documentation and related content on page 1 Important Changing some IDs or passwords without proper planning for example the IMM on any of the System x3650 M5 servers will affect the overall configuration for the cluster Password criteria The following password criteria are strongly recommended by Lenovo s Software Security Review Board No less than twenty 20 cha...

Страница 18: ...10 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 19: ...Pro for XClarity Administrator Customer Software is loaded in manufacturing Customer must log in to Lenovo XClarity Administrator and accept the license Additional licenses might be available for purchase during the ThinkAgile SXM ordering process Microsoft Azure Stack subscription and billing A Microsoft Azure Stack subscription should be obtained by the customer prior to the deployment engagemen...

Страница 20: ...12 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 21: ... Best Recipe and Support impact The ThinkAgile SXM Best Recipe includes component firmware levels that have been tested in an appropriate environment Any specific firmware that is above or below the level indicated in the Best Recipe is not supported and might impact Lenovo s ability to support any issues with the relevant component or the entire solution Updating firmware See ThinkAgile SXM docum...

Страница 22: ...14 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 23: ...int to point diagrams and tables 6 Check the firmware level for the switch To determine the current version of firmware on the switch use the Industry Standard CLI ISCLI command show version brief For information about the ISCLI refer to the ISCLI Industry Standard CLI Command Reference for the switch that you are replacing 7 If the firmware level is not at the Best Recipe level update the firmwar...

Страница 24: ...rmware maintenance and Best Recipe on page 13 for more information 8 Use Lenovo XClarity Administrator to apply the Microsoft Azure Stack pattern UEFI settings 9 Reconfigure the RAID 1 boot volume Replacing server parts ThinkAgile SXM products require specific server configuration Use the following tips to help ensure successful part replacement Important This information applies to all ThinkAgile...

Страница 25: ...etwork adapter 1 Reconnect the cables according to the point to point diagrams and tables 2 Use Lenovo XClarity Administrator to update the adapter firmware See Chapter 6 Firmware maintenance and Best Recipe on page 13 Memory No solution specific configuration is required after replacement CPU No solution specific configuration is required after replacement Chapter 7 Component service and replacem...

Страница 26: ...18 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 27: ...ze the correct entitlement which could delay proper case handling You can find the product serial number on the rack label Product Machine Type and Model The Machine Type for the ThinkAgile SXM is 9565 See the table above for the specific Model Note that the product designation for example SXM4200 is not the Model Getting support See Chapter 9 Working with service and support on page 27 for specif...

Страница 28: ... SXM products ThinkAgile SXM Support page For the latest information and links to helpful content refer to the Lenovo Data Center Support page You can search for support information for ThinkAgile SXM and other Lenovo products See the following Web site https datacentersupport lenovo com Other documentation See ThinkAgile SXM documentation and related content on page 1 for relevant links including...

Страница 29: ...gs are correct Ensure that the border switch settings are correct Check for any errors in the switch configuration file Check the data path Ping between the next hop interfaces from the RackSwitch G8052 and RackSwitch G8272 switches Check the gateway Each switch in the solution should be able to ping the point to point links and IP addresses of the other switches Test the connection between the se...

Страница 30: ...t be useful in issue resolution see Collecting data on page 28 Isolating network problems Use the following procedures and tips to resolve ThinkAgile SXM network issues that might arise Deployment issues The following issues could arise during solution deployment These would typically be resolved by Lenovo Professional Services and ThinkAgile Advantage Support Issue During deployment the PXE Boot ...

Страница 31: ...e the port RackSwitch G8052 ENOS a Use interface port port_number to enter interface configuration mode b Use shutdown to disable the port c Use no shutdown to enable the port RackSwitch G8272 CNOS a Use interface eth 1 port_number to enter interface configuration mode b Use shutdown to disable the port c Use no shutdown to enable the port Spanning Tree troubleshooting Use the following procedure ...

Страница 32: ...rm whether the RackSwitch G8272 switches can ping the gateway ping G8052_management_ port_IP vrf management 3 Verify the IP ARP table for the management interface RackSwitch G8052 ENOS show ip arp RackSwitch G8272 CNOS display ip arp vrf management 4 Check the management port state vLAG troubleshooting Use the following procedure to the troubleshoot vLAG issues on the RackSwitch G8272 switches 1 E...

Страница 33: ...he BGP injected routes from the downlink and verify that the routes are advertised to the uplink RackSwitch G8052 ENOS show ip bgp information RackSwitch G8272 CNOS display ip bgp Use the following commands to check the route map and prefix list configuration on the RackSwitch G8272 display run route map display run prefix list If necessary use the shut and no shut commands to disable then enable ...

Страница 34: ...26 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 35: ...es Your ThinkAgile SXM is entitled at the rack level and is identified by the serial number associated with Machine Type 9565 You can find the serial number on the rack label Before contacting ThinkAgile Advantage Support Gather the following information to provide to the technical support agent This data will help the agent quickly provide a product to your problem and ensure that you receive the...

Страница 36: ...cluding the applicable phone number for your country Important Be sure to record the case number that you are given It will be necessary for uploading data and tracking your case Collecting data This topic describes how to collect ThinkAgile SXM product data that might be needed for troubleshooting or when working with ThinkAgile Advantage Support ThinkAgile SXM serial number Your ThinkAgile SXM i...

Страница 37: ...port ftp sftp server_URL copy flash dump ftp sftp server_URL For the RackSwitch G8272 use the following CNOS commands to gather data The user must be in Privileged EXEC mode display tech support cp tech support ftp scp sftp tftp server_URL timeout timeout_interval vrf default management See ThinkAgile SXM documentation and related content on page 1 for links to relevant documentation Sending data ...

Страница 38: ...30 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 39: ... hardware The System x3550 M5 server functions as the Hardware Lifecycle Host The RackSwitch G8052 switch functions as the BMC switch The RackSwitch G8272 switches function as the TOR switches SXM4200 25U rack views model RCC The SXM4200 in the 25U rack is Machine Type 9565 Model RCC This model is available with four to eight System x3650 M5 servers Figure 1 Front view of SXM4200 in 25U rack Copyr...

Страница 40: ... the 42U rack is Machine Type 9565 Model RCD This model is available with four to twelve System x3650 M5 servers Note The PDUs for the 42U rack are housed in compartments in the rack side wall and do not use rack slots 32 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 41: ...Figure 3 Front view of SXM4200 in 42U rack Appendix A SXM4200 SXM6200 models 33 ...

Страница 42: ...6200 rack views model RCE The SXM6200 is Machine Type 9565 Model RCE Note The PDUs for the 42U rack are housed in compartments in the rack side wall and do not use rack slots 34 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 43: ...Figure 5 Front view of SXM6200 Appendix A SXM4200 SXM6200 models 35 ...

Страница 44: ...PDUs Configurations Depending on the model ThinkAgile SXM products are available in either a 25U or a 42U rack The product contains the following hardware Four to twelve System x3650 M5 server nodes depending on model and configuration ordered One System x3550 M5 server which acts as the Hardware Lifecycle Host Two RackSwitch G8272 TOR switches 36 Lenovo ThinkAgile SX for Microsoft Azure Stack Adm...

Страница 45: ...igure 7 Views of System x3650 M5 server nodes Note The LOM ports on the rear are disabled by default in UEFI this is done during manufacturing Hardware Lifecycle Host The following images show the System x3550 M5 HLH Figure 8 Views of System x3550 M5 HLH Note The LOM ports on the rear are disabled by default in UEFI this is done during manufacturing Top of rack switches The following image shows t...

Страница 46: ... SXM4200 SXM6200 network and management cabling The ThinkAgile SXM product is precabled for the management and data networks This information is provided for your reference The following image shows the network and management cabling connections for the ThinkAgile SXM SXM4200 and SXM6200 models 38 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 47: ...s 49 and 50 Switch Health 10 GbE The RackSwitch G8272 TOR switches are connected to each other for heartbeat loopback on Port 45 Management 1 GbE Ports 1 12 of the RackSwitch G8052 BMC switch are connected to the dedicated IMM port on each System x3650 M5 node Port 46 of the RackSwitch G8052 BMC switch is connected to the dedicated IMM port on the System x3550 M5 HLH Port 47 of the RackSwitch G805...

Страница 48: ...200 network cabling for RackSwitch G8272 TOR Switch 2 Source Port Destination Connection type Device Port Optic 54 Reserved n a n a n a 53 Reserved n a n a n a 52 Reserved n a n a n a 51 Reserved n a n a n a 50 RackSwitch G8272 Switch 1 TOR 50 n a QSFP QSFP TwinAx 1m 49 RackSwitch G8272 Switch 1 TOR 49 n a QSFP QSFP TwinAx 1m 48 Border 2 Customer 10G SR LC LC Fibre Customer 47 Border 1 Customer 10...

Страница 49: ...ver Node 11 Mellanox P2 n a SFP SFP TwinAx 3m 10 System x3650 M5 Server Node 10 Mellanox P2 n a SFP SFP TwinAx 3m 9 System x3650 M5 Server Node 9 Mellanox P2 n a SFP SFP TwinAx 3m 8 System x3650 M5 Server Node 8 Mellanox P2 n a SFP SFP TwinAx 3m 7 System x3650 M5 Server Node 7 Mellanox P2 n a SFP SFP TwinAx 3m 6 System x3650 M5 Server Node 6 Mellanox P2 n a SFP SFP TwinAx 3m 5 System x3650 M5 Serv...

Страница 50: ... BMC 51 n a SFP SFP TwinAx 1m 45 RackSwitch G8272 Switch 2 TOR 45 n a SFP SFP TwinAx 1m 44 RackSwitch G8272 Switch 2 TOR 44 n a SFP SFP TwinAx 1m 43 n a n a n a n a 42 n a n a n a n a 41 n a n a n a n a 40 n a n a n a n a 39 n a n a n a n a 38 n a n a n a n a 37 n a n a n a n a 36 n a n a n a n a 35 n a n a n a n a 34 n a n a n a n a 33 n a n a n a n a 32 n a n a n a n a 31 n a n a n a n a 30 n a ...

Страница 51: ...r Node 5 Mellanox P1 n a SFP SFP TwinAx 3m 4 System x3650 M5 Server Node 4 Mellanox P1 n a SFP SFP TwinAx 3m 3 System x3650 M5 Server Node 3 Mellanox P1 n a SFP SFP TwinAx 3m 2 System x3650 M5 Server Node 2 Mellanox P1 n a SFP SFP TwinAx 3m 1 System x3650 M5 Server Node 1 Mellanox P1 n a SFP SFP TwinAx 3m Console n a n a n a n a MGMT n a 47 n a Cat5e 1 5m Table 4 SXM4200 SXM6200 network cabling fo...

Страница 52: ...a n a 29 n a n a n a n a 28 n a n a n a n a 27 n a n a n a n a 26 n a n a n a n a 25 n a n a n a n a 24 n a n a n a n a 23 n a n a n a n a 22 n a n a n a n a 21 n a n a n a n a 20 n a n a n a n a 19 n a n a n a n a 18 n a n a n a n a 17 n a n a n a n a 16 n a n a n a n a 15 n a n a n a n a 14 n a n a n a n a 13 n a n a n a n a 12 System x3650 M5 Server Node 12 BMC n a Cat5e 3m 11 System x3650 M5 S...

Страница 53: ... Server Node 7 BMC n a Cat5e 3m 6 System x3650 M5 Server Node 6 BMC n a Cat5e 3m 5 System x3650 M5 Server Node 5 BMC n a Cat5e 3m 4 System x3650 M5 Server Node 4 BMC n a Cat5e 3m 3 System x3650 M5 Server Node 3 BMC n a Cat5e 3m 2 System x3650 M5 Server Node 2 BMC n a Cat5e 3m 1 System x3650 M5 Server Node 1 BMC n a Cat5e 3m Console n a n a n a n a MGMT n a n a n a n a Appendix A SXM4200 SXM6200 mo...

Страница 54: ...46 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 55: ...he ThinkSystem NE2572 switches function as the TOR switches SXM4400 25U rack views model RCH The SXM4400 in the 25U rack is Machine Type 9565 Model RCH This model is available with four to eight ThinkSystem SR650 servers Figure 12 Front view of SXM4400 in 25U rack SXM4400 42U rack views model RCJ The SXM4400 in the 42U rack is Machine Type 9565 Model RCD This model is available with four to twelve...

Страница 56: ... SXM6400 is Machine Type 9565 Model RCK This model is equipped with twelve ThinkSystem SR650 servers Note The PDUs for the 42U rack are housed in compartments in the rack side wall and do not use rack slots 48 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 57: ...l ThinkAgile SXM products are available in either a 25U or a 42U rack The product contains the following hardware Four to twelve ThinkSystem SR650 server nodes depending on model and configuration ordered One ThinkSystem SR630 server which acts as the Hardware Lifecycle Host Two ThinkSystem NE2572 TOR switches The Lenovo Cloud Networking Operating System CNOS is installed on these switches One Rac...

Страница 58: ...server nodes Note The LOM ports on the rear are disabled by default in UEFI this is done during manufacturing Hardware Lifecycle Host The following images show the ThinkSystem SR630 HLH Figure 16 Views of ThinkSystem SR630 HLH Note The LOM ports on the rear are disabled by default in UEFI this is done during manufacturing 50 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 59: ...ch Management switch The following image shows the RackSwitch G8052 BMC switch Figure 18 View of RackSwitch G8052 BMC switch SXM4400 SXM6400 network and management cabling The ThinkAgile SXM product is precabled for the management and data networks This information is provided for your reference The following image shows the network and management cabling connections for the ThinkAgile SXM SXM4400...

Страница 60: ...ackSwitch G8052 BMC switch are connected to the dedicated XCC port on each ThinkSystem SR650 node Port 46 of the RackSwitch G8052 BMC switch is connected to the dedicated XCC port on the ThinkSystem SR630 HLH Port 47 of the RackSwitch G8052 BMC switch is connected to the MGMT port of ThinkSystem NE2572 TOR switch 1 Port 48 of the RackSwitch G8052 BMC switch is connected to the MGMT port of ThinkSy...

Страница 61: ...n a n a 53 Reserved n a n a n a 52 Reserved n a n a n a 51 Reserved n a n a n a 50 ThinkSystem NE2572 Switch 1 TOR 50 n a QSFP28 QSFP28 AOC 1m 49 ThinkSystem NE2572 Switch 1 TOR 49 n a QSFP28 QSFP28 AOC 1m 48 Border 2 Customer 10 25G SR LC LC Fibre Customer 47 Border 1 Customer 10 25G SR LC LC Fibre Customer 46 n a n a n a n a 45 n a n a n a n a 44 ThinkSystem NE2572 Switch 1 TOR 44 n a SFP28 SFP2...

Страница 62: ...Server Node 10 Mellanox P2 n a SFP28 SFP28 TwinAx 3m 9 ThinkSystem SR650 Server Node 9 Mellanox P2 n a SFP28 SFP28 TwinAx 3m 8 ThinkSystem SR650 Server Node 8 Mellanox P2 n a SFP28 SFP28 TwinAx 3m 7 ThinkSystem SR650 Server Node 7 Mellanox P2 n a SFP28 SFP28 TwinAx 3m 6 ThinkSystem SR650 Server Node 6 Mellanox P2 n a SFP28 SFP28 TwinAx 3m 5 ThinkSystem SR650 Server Node 5 Mellanox P2 n a SFP28 SFP...

Страница 63: ...r 46 n a n a n a n a 45 n a n a n a n a 44 ThinkSystem NE2572 Switch 2 TOR 44 n a SFP28 SFP28 TwinAx 1m 43 ThinkSystem NE2572 Switch 2 TOR 43 n a SFP28 SFP28 TwinAx 1m 42 n a n a n a n a 41 n a n a n a n a 40 RackSwitch G8052 Switch BMC 51 n a SFP SFP TwinAx 1m 39 n a n a n a n a 38 n a n a n a n a 37 n a n a n a n a 36 n a n a n a n a 35 n a n a n a n a 34 n a n a n a n a 33 n a n a n a n a 32 n ...

Страница 64: ...0 Server Node 5 Mellanox P1 n a SFP28 SFP28 TwinAx 3m 4 ThinkSystem SR650 Server Node 4 Mellanox P1 n a SFP28 SFP28 TwinAx 3m 3 ThinkSystem SR650 Server Node 3 Mellanox P1 n a SFP28 SFP28 TwinAx 3m 2 ThinkSystem SR650 Server Node 2 Mellanox P1 n a SFP28 SFP28 TwinAx 3m 1 ThinkSystem SR650 Server Node 1 Mellanox P1 n a SFP28 SFP28 TwinAx 3m Console n a n a n a n a MGMT n a 47 n a Cat5e 1 5m Table 7...

Страница 65: ...a n a n a 30 n a n a n a n a 29 n a n a n a n a 28 n a n a n a n a 27 n a n a n a n a 26 n a n a n a n a 25 n a n a n a n a 24 n a n a n a n a 23 n a n a n a n a 22 n a n a n a n a 21 n a n a n a n a 20 n a n a n a n a 19 n a n a n a n a 18 n a n a n a n a 17 n a n a n a n a 16 n a n a n a n a 15 n a n a n a n a 14 n a n a n a n a 13 n a n a n a n a 12 ThinkSystem SR650 Server Node 12 BMC n a Cat5...

Страница 66: ...a Cat5e 3m 6 ThinkSystem SR650 Server Node 6 BMC n a Cat5e 3m 5 ThinkSystem SR650 Server Node 5 BMC n a Cat5e 3m 4 ThinkSystem SR650 Server Node 4 BMC n a Cat5e 3m 3 ThinkSystem SR650 Server Node 3 BMC n a Cat5e 3m 2 ThinkSystem SR650 Server Node 2 BMC n a Cat5e 3m 1 ThinkSystem SR650 Server Node 1 BMC n a Cat5e 3m Console n a n a n a n a MGMT n a n a n a n a 58 Lenovo ThinkAgile SX for Microsoft ...

Страница 67: ... pre installed on the Hardware Lifecycle Host server The customer must provide the license key during the deployment engagement Microsoft Hyper V is included in order to host the LXCA VMs Microsoft Windows Server 2016 Datacenter This product is pre installed on the server nodes The customer must provide the license key during the deployment engagement Microsoft Hyper V is included in order to host...

Страница 68: ...60 Lenovo ThinkAgile SX for Microsoft Azure Stack Administrator s Guide ...

Страница 69: ...rack Source Destination Connection type PDU Port Device Port PDU 4 12 Top of Rack switch 1 PSU 2 C13 C14 PDU 4 11 Hardware Lifecycle Host PSU 2 C13 C14 PDU 4 10 not used n a n a PDU 4 9 not used n a n a PDU 4 8 not used n a n a PDU 4 7 not used n a n a PDU 4 6 not used n a n a PDU 4 5 not used n a n a PDU 4 4 Server node 8 PSU 2 C13 C14 PDU 4 3 Server node 7 PSU 2 C13 C14 PDU 4 2 Server node 6 PSU...

Страница 70: ...PDU 1 8 not used n a n a PDU 1 7 not used n a n a PDU 1 6 not used n a n a PDU 1 5 not used n a n a PDU 1 4 Server node 4 PSU 1 C13 C14 PDU 1 3 Server node 3 PSU 1 C13 C14 PDU 1 2 Server node 2 PSU 1 C13 C14 PDU 1 1 Server node 1 PSU 1 C13 C14 PDU 1 MGMT not used n a n a Power cabling for 42U rack The following table shows the power cabling for the ThinkAgile SXM 42U rack models These settings app...

Страница 71: ...n a n a PDU 3 9 not used n a n a PDU 3 8 not used n a n a PDU 3 7 not used n a n a PDU 3 6 not used n a n a PDU 3 5 not used n a n a PDU 3 4 Server node 12 PSU 1 C13 C14 PDU 3 3 Server node 11 PSU 1 C13 C14 PDU 3 2 Server node 10 PSU 1 C13 C14 PDU 3 1 Server node 9 PSU 1 C13 C14 PDU 3 MGMT not used n a n a PDU 2 12 Top of Rack switch 2 PSU 2 C13 C14 PDU 2 11 Top of Rack switch 1 PSU 2 C13 C14 PDU ...

Страница 72: ...C13 C14 PDU 1 10 Management switch PSU 1 C13 C14 PDU 1 9 Hardware Lifecycle Host PSU 1 C13 C14 PDU 1 8 Server node 8 PSU 1 C13 C14 PDU 1 7 Server node 7 PSU 1 C13 C14 PDU 1 6 Server node 6 PSU 1 C13 C14 PDU 1 5 Server node 5 PSU 1 C13 C14 PDU 1 4 Server node 4 PSU 1 C13 C14 PDU 1 3 Server node 3 PSU 1 C13 C14 PDU 1 2 Server node 2 PSU 1 C13 C14 PDU 1 1 Server node 1 PSU 1 C13 C14 PDU 1 MGMT not us...