2. If you are instructed to return the old hot-swap drive, follow all packaging instructions and use any
packaging materials that are provided.
Install a hot-swap drive
Use this information to install a hot-swap drive.
Ground package before opening”
The following notes describe the type of drives that your server supports and other information that you must
consider when you install a drive.
• Depending on your server models, your server supports the following types of drives:
– SAS/SATA HDD
– SAS/SATA SSD
– NVMe SSD
For a list of supported drives, see:
http://www.lenovo.com/us/en/serverproven/
• The drive bays are numbered to indicate the installation order (starting from number “0”). Follow the
installation order when you install a drive. See “Front view” on page 13.
• You can mix drives of different types and different capacities in one system, but not in one RAID array.
The following order is recommended when installing the drives:
– Drive type priority: NVMe SSD, SAS SSD, SATA SSD, SAS HDD, SATA HDD
– Drive capacity priority: the lowest capacity first
• For server models with ten 2.5-inch drive bays in the front, NVMe drives are supported in drive bays 6–9.
• The drives in a single RAID array must be the same type, same size, and same capacity.
Before installing a hot-swap drive:
1. Remove the drive filler from the drive bay. Keep the drive filler in a safe place.
Figure 22. Drive filler removal
.
Hardware replacement procedures
49
Содержание ThinkAgile MX3321-F
Страница 1: ...ThinkAgile MX Certified Node 1U ThinkAgile MX3321 H MX3321 F User Guide Machine Type 7D1H ...
Страница 32: ...28 ThinkAgile MX Certified Node 1UThinkAgile MX3321 H MX3321 FUser Guide ...
Страница 118: ...114 ThinkAgile MX Certified Node 1UThinkAgile MX3321 H MX3321 FUser Guide ...
Страница 125: ......
Страница 126: ......